UL DLC listed LED linear high bay light 130lm/W flicker free with 1-10V dimming function close-up
K-02 · Linear High Bay Lights

Linear High Bay Light A-LHB-NV(HV)xK-02

160W to 320W Linear High Bay — Built for the Warehouse That Runs Around the Cloc

SKU: A-LHB4FT-160W-NV5K-02|
In Stock
UL Listed
🛡️IP65
ETL Listed
5-Year Warranty
$130.00

Volume pricing available

Pro & Volume Pricing Available

Contractors, distributors, and trade partners — create a Pro account for exclusive pricing, or request a quote for multi-unit projects.

In Stock — Ships within 1-2 business days from CA
Free shipping on orders over $499
Need help? (626) 364-9198 or sales@auvolar.com

160W to 320W Linear High Bay — Built for the Warehouse That Runs Around the Clock.

UL + FCC listed with flicker-free operation, 1-10V dimming, and a high-efficiency isolated driver (>87% efficiency, PF>0.9, THD<20%). Designed for warehouses, gymnasiums, and industrial spaces where 24/7 operation demands fixtures that don't flicker, overheat, or fail.

Flicker-Free Operation for 8-12 Hour Work Shifts

Workers under flickering lights experience headaches, eye strain, and reduced productivity. This fixture's low-THD driver (<20%) eliminates visible flicker, which matters when your team is under these lights for full shifts, every day.

Isolated Driver Prevents Electrical Failures from Cascading

An isolated driver design means a power surge or line noise event affects only the driver, not the LED array. In industrial facilities with heavy machinery on the same circuit, electrical isolation extends fixture life dramatically.

1-10V Dimming for Energy Management and Daylight Harvesting

Connect to building automation for scheduled dimming, daylight harvesting, and demand response. Facilities with skylights or clerestory windows can reduce lighting energy by 30–50% during daylight hours.

Dry and Damp Location Rated — Warehouse Through Loading Dock

Approved for both dry interior warehouse zones and damp areas near loading docks and entrances where temperature differentials cause condensation. One fixture handles the entire facility.

160W, 165W, 225W, 320W — Granular Wattage Selection

Four specific wattage options let you match the fixture to the exact lighting requirement. No need to over-specify a 320W fixture for an area that only needs 160W — save energy and money on every mounting point.

Efficacy

130 lm/W
High-efficiency operation for 24/7 industrial facilities

THD

<20%
Ultra-low harmonic distortion — no visible flicker

Driver Efficiency

>87%
Less power wasted as heat, more delivered as light

Warranty

5 Years
Full coverage for demanding industrial environments

LightSpec AI

Free Lighting Layout
IES-based photometric simulation
130 lm/W
Efficacy
<20%
THD
>87%
Driver Efficiency
5 Years
Warranty

Electrical

Wattage160W, 165W, 225W and 320W power options with C
Power Factor0.9
Voltage120-277V
Dimming1-10V High Bay LED Light for Warehouse Industrial
THD<20%

Optical

Efficacy130lm/W
Lumens130lm
CCTchoices of 4000K and 5000K (Ra80)
CRI80
CCT Options4000K / 5000K

Physical

IP RatingDry/Damp location
MountingChain mounting

Certification

CertificationsUL, FCC
UL ListedULus & FCC listed
FCCYes

Warranty

Warranty5-Year Warranty

Photometric Performance Data

Professional IES-standard luminous flux measurements at 25°C, 4000K Ra70. Data certified for lighting design calculations and municipal specifications.

Standards Compliance

Based on max wattage lumen output per optic. Actual compliance depends on layout design and fixture count.

🏆
FIFA A
≥ 2400 lux avg
120°
FIFA C
≥ 1000 lux avg
120°
🏈
IES RP-6 Class I
≥ 100 fc avg
120°
🎾
IES RP-6 Class III
≥ 30 fc avg
120°

Beam Pattern & CBCP

Peak Center Beam Candlepower and throw ratings by optic.

120°
120° optic
Peak CBCP13,242 cd
Beam Angle120°
Throw RatingWide Flood (<30ft)
Wide area coverage · Low-mount <30ft · Recreational

⚡ Quick Project Estimator

Select your sport and level for an instant fixture recommendation.

Recommended Optic
60°
Fixture Count
48-72
Pole Layout
4-6 poles
Target Level
500-1000 lux (FIFA C/D)
Mounting Height
50-60ft
Get Full Photometric Layout (Free) →

Custom AGi32-grade simulation with foot-candle grid, uniformity ratios, and pole spacing

Lumen Output (lm)

Tested per IESNA LM-79-19 at 25°C, EVERFINE GO-2000A goniophotometer

Optic160W165W225W320W
120° ()20,80021,45029,25041,600
Efficacy (lm/W)130130130130

Efficacy Comparison

lm/W — higher is better

Light A-LHB-NV(HV)xK-02 (this product)
130 lm/W
Industry LED Average
130 lm/W
HPS (High-Pressure Sodium)
110 lm/W
Metal Halide
90 lm/W

* Peak efficacy measured from LM-79 test data. Competitor values are industry typical ranges.

🔆 Run a Free Photometric Simulation

Upload your floor plan and let LightSpec AI calculate foot-candle levels, uniformity ratios, and recommended pole spacing — in under 60 seconds.

Try LightSpec AI →

💡 LED Upgrade ROI Calculator

See the financial case for switching to LED in seconds.

Annual Energy Savings
$3,784
💰
Energy Reduction
54.0%
Payback Period
4.0 yrs
10-Year Net Savings
$22,843
CO₂ Reduction
13.5 tons/yr
DLC Utility Rebate Estimate
$2,000
~$100/fixture avg
Payback timeline4.0 of 10 yrs

* Calculations based on standard operating conditions. Actual savings depend on local utility rates and rebate availability. CO₂ based on EPA eGRID national avg (0.855 lbs/kWh).

Heavy-Duty Linear High Bay for Maximum Output Environments

The A-LHB-02 delivers 160–320W of aisle-optimized linear illumination with UL + ETL dual certification and IP65 protection — engineered for the tallest VNA warehouses, demanding production lines, and high-ceiling commercial spaces.

📦

VNA & Racking Aisle Warehouses

Third-party logistics (3PL) facilities with 40–50 ft clear heights and 5–6 ft VNA aisles represent the most demanding lighting application in warehousing — requiring high-lumen vertical illuminance deep into rack canyons where turret truck operators pick at heights exceeding 35 ft. The A-LHB-02 at 160–320W delivers up to 51,200 lumens in a linear form factor that directs output precisely down the aisle corridor, achieving the ≥1 fc vertical illuminance at the highest pick face mandated by IES RP-7-21. At these mounting heights, round UFO fixtures lose 40–60% of useful output to rack tops and cross-aisle spill. The 320W model replaces 750–1,000W metal halide with 55–68% energy savings, and the 0-10V dimming interface enables aisle-by-aisle occupancy switching that delivers an additional 35–45% savings in facilities with <50% aisle utilization at any given time. UL + ETL dual certification satisfies all U.S. jurisdictions including strict AHJ requirements. IP65 handles the significant airborne dust in high-traffic concrete-floor 3PL operations. Generate a free LightSpec AI vertical illuminance study with your exact rack height and aisle width to validate compliance before specifying.

Standard: IES RP-7-21 / OSHA 29 CFR 1926.56 / ASHRAE 90.1-2022

Technical Requirements

  • 30–50 fc horizontal illuminance at floor level
  • ≥1 fc vertical illuminance at highest pick face (IES RP-7-21)
  • Vertical uniformity ≤3:1 from floor to top rack level
  • IP65 for heavy dust and forklift traffic environments
  • 0-10V dimming for per-aisle occupancy control
  • L70 ≥100,000 hours — high-ceiling re-lamping costs $150–$300/fixture

Recommended Specifications

280–320W for 35–50 ft mounting heights in tall VNA facilities160–240W for 25–35 ft standard high-rack warehouses5000K CCT for barcode contrast and label readability at heightAsymmetric aisle optics for maximum rack-face penetrationContinuous row mounting aligned over aisle centerlines

Installation Notes

  • Precision-align fixture centerline over aisle center — at 40+ ft heights, even 8 in. lateral offset reduces vertical fc on one rack face by 20%
  • Use continuous mounting channel (Unistrut or equivalent) for straight-line alignment across long aisle runs
  • Wire to 480V input to reduce conductor gauge by 2 sizes on 200+ ft aisle runs, saving significant copper cost
  • Program occupancy sensors with 5-minute hold time and 50% standby dimming — full blackout creates forklift safety hazards

Regional Compliance Notes

California Title 24-2022 mandates occupancy controls in warehouse aisles — A-LHB-02 0-10V is compliant

ASHRAE 90.1-2022 warehouse LPD is 0.66 W/sf — A-LHB-02 achieves 0.3–0.5 W/sf

🏭

Assembly Line & Production Facilities

Heavy manufacturing facilities with 30–45 ft bays housing large equipment — stamping presses, CNC machining centers, robotic welding cells — require high-output linear illumination that can be mounted above crane rails while still delivering 50–100 fc at the work surface 25–35 ft below. The A-LHB-02 at 320W produces approximately 51,200 lumens in a 4-foot linear body, creating continuous light lines that eliminate the inter-fixture dark zones where quality defects go undetected on moving production lines. IES RP-7-21 and IESNA DG-29 specify ≤2:1 uniformity for precision manufacturing — achievable with 12–15 ft row spacing at 30 ft mounting height. The IP65-rated housing withstands the metalworking fluid aerosol, grinding dust, and high-pressure cleaning common in heavy industrial environments without the seal degradation that forces premature replacement of lower-IP fixtures. At 160 lm/W class efficacy, the A-LHB-02 typically operates at 0.5–0.7 W/sf — well below the ASHRAE 90.1 manufacturing allowance of 0.85 W/sf. UL + ETL dual listing streamlines the permitting process across all jurisdictions. Run a free LightSpec AI simulation to model task-plane illuminance at each workstation before finalizing your fixture schedule.

Standard: IES RP-7-21 / OSHA 1910.303 / NFPA 70 / IESNA DG-29

Technical Requirements

  • 50–100 fc at work surface (36–42 in. AFF) depending on task precision
  • CRI ≥80; ≥90 for color-critical QC and inspection stations
  • Flicker <1% at all output levels for machine vision systems
  • Longitudinal uniformity ≤1.5:1 along continuous production lines
  • IP65 for metalworking fluid, grinding dust, and wash-down
  • L70 100,000 hours to minimize production-disrupting maintenance

Recommended Specifications

280–320W for 30–45 ft ceiling heights over heavy production bays160–240W for 20–30 ft in sub-assembly and inspection areas4000K general assembly; 5000K for inspection stationsContinuous row mounting for seamless illumination along production flow0-10V daylight harvesting where monitor/skylight systems exist

Installation Notes

  • Mount above crane rail height with 24 in. minimum clearance — verify with crane manufacturer specifications
  • Use seismic-rated mounting brackets in California and high-seismic zones per IBC requirements
  • Dedicate lighting circuits separate from VFD-driven equipment to prevent harmonic-induced flicker

Regional Compliance Notes

California Title 24 Section 140.6 requires automatic daylight controls in manufacturing with ≥2% skylight area

ASHRAE 90.1-2022 manufacturing LPD is 0.85 W/sf — A-LHB-02 operates at 0.5–0.7 W/sf

🛒

Retail Warehouse & Home Improvement

Large-format home improvement and building supply retailers operate in 80,000–140,000 sf facilities with 25–35 ft open ceilings and 15–25 ft product racking that creates deep aisle canyons where traditional point-source lighting cannot maintain acceptable vertical illuminance on merchandise faces. The A-LHB-02 linear form factor directs light along the aisle corridor, delivering 50–75 fc at shelf face with CRI >80 for accurate color rendering of paint, flooring, tile, and lumber — product categories where color accuracy directly affects purchase decisions and return rates. At 160–320W producing up to 51,200 lumens, a single fixture covers 20–30 linear feet of aisle depending on mounting height, reducing total fixture count by 30–40% compared to UFO alternatives while achieving superior vertical uniformity. UL + ETL certification ensures seamless building permit approval across all jurisdictions. The 100,000-hour life eliminates the $20–$30/fixture re-lamping cost every 2–3 years that retail chains budget for HID technology. Design your aisle lighting layout free with LightSpec AI to optimize fixture count and minimize over-lighting in cross-aisle intersections.

Standard: IES RP-2-22 / IES Retail Lighting Guide / ASHRAE 90.1-2022

Technical Requirements

  • 50–75 fc at shelf face height (3–10 ft AFF) in merchandise aisles
  • Vertical uniformity ≤3:1 from bottom to top shelf
  • CRI ≥80 for paint, tile, and flooring color accuracy
  • Flicker-free for security cameras and customer smartphone video
  • 0-10V dimming for after-hours energy management
  • UL + ETL for universal commercial occupancy compliance

Recommended Specifications

240–320W for 28–35 ft ceilings in main retail aisle bays160–200W for 20–25 ft in checkout and seasonal areas4000K CCT for warm-neutral retail environmentLinear aisle optics aligned parallel with merchandise corridorsContinuous rows for consistent illumination without dark gaps

Installation Notes

  • Orient fixtures parallel to aisle direction — perpendicular mounting wastes 30%+ output on rack tops
  • Space at ≤1.0× mounting height in retail aisles for ≤3:1 uniformity at shelf face
  • Feed from 277V commercial panels for long aisle circuit runs within NEC ampacity limits

Regional Compliance Notes

California Title 24-2022 retail LPD is 1.0 W/sf — A-LHB-02 achieves 50–75 fc within 0.5–0.7 W/sf

Washington and Oregon energy codes require daylight controls in retail spaces with skylights

❄️

Cold Storage & Freezer Aisles

Industrial cold chain distribution centers operating at -20°F to 35°F with narrow pick aisles between pallet racks present a dual challenge: extreme environmental conditions that destroy standard fixtures, and narrow aisle geometry that demands directional light distribution. The A-LHB-02 addresses both with IP65 fully gasketed construction rated to -40°F and a linear optical path that concentrates output down narrow freezer aisles instead of wasting lumens on pallet rack tops. At 160–320W delivering up to 51,200 lumens, the fixture provides the 15–25 fc required by IES RP-7 for cold storage while consuming 60–75% less power than the HPS and metal halide fixtures still operating 24/7 in legacy cold chain facilities. The die-cast aluminum housing with UV-stabilized powder coat resists ammonia refrigerant exposure and chlorinated wash-down chemicals that degrade painted-steel housings within 18 months. UL + ETL certification is mandatory for cold storage facility insurers and operators in most U.S. markets. At typical cold storage electricity rates and 24/7 operation, each 200W fixture saves $420–$550/year versus a 400W HPS — achieving ROI in under 12 months before utility rebates. Use LightSpec AI to model freezer aisle coverage free.

Standard: IES RP-7-21 / NSF/ANSI 2 / USDA FSIS / ASHRAE 90.1

Technical Requirements

  • IP65 sealed against ice crystal formation, humidity, and wash-down
  • Operating range -40°F to 131°F (-40°C to 55°C) including driver
  • 15–25 fc at floor level in freezer aisles; 30 fc at inspection zones
  • Corrosion-resistant to ammonia and chlorinated cleaning chemicals
  • Smooth housing surfaces for USDA/FDA sanitation protocol compliance
  • UL + ETL certification for cold storage insurance requirements

Recommended Specifications

240–320W for 30–40 ft freezer warehouse heights160–200W for 20–28 ft cold storage aisle corridors5000K CCT for date code and product label inspection316 stainless steel mounting hardware exclusivelyEmergency battery backup for egress-required freezer corridors

Installation Notes

  • Install during controlled temperature equalization — do not energize fixtures cold-soaked below -20°F without minimum 30-minute warm-up
  • Use 316 stainless steel exclusively for all fasteners and hardware — lesser grades corrode within months
  • Seal all conduit penetrations through insulated walls with fire-rated, vapor-tight sealant to prevent thermal bridging

Regional Compliance Notes

California Title 24 requires UL/ETL listing for cold storage fixtures receiving utility rebates or incentives

ASHRAE 90.1 cold storage LPD is 0.6 W/sf — A-LHB-02 achieves 0.25–0.45 W/sf

🏋️

Fitness & Indoor Recreation Centers

Large gymnasium vaults with 35–45 ft peak heights — common in high school, university, and community recreation centers — demand high-output fixtures that can deliver 50–75 fc at court level from extreme mounting distances while maintaining the strict glare control IES RP-6 requires for athletic spaces. The A-LHB-02 at 280–320W produces 44,800–51,200 lumens in a linear form factor that creates uniform light lines across court surfaces, eliminating the bright spot/dark gap scalloping pattern that UFO fixtures create at wide spacing. This uniformity is critical for ball tracking — IES RP-6 requires vertical illuminance ≥50% of horizontal at net and basket height to prevent "lost ball" visual interruptions during play. The linear form factor also integrates more aesthetically with the exposed steel structure common in modern gymnasiums, avoiding the "UFO invasion" appearance that architects reject. 0-10V dimming enables multi-scene programming: 100% for competition, 70% for practice, 40% for fitness classes, 20% for cleaning. At 160–320W the A-LHB-02 achieves 0.5–0.8 W/sf — well within ASHRAE 90.1's 1.1 W/sf gymnasium allowance. UL + ETL certified. Model your gymnasium free with LightSpec AI to confirm court-level uniformity and glare angles.

Standard: IES RP-6-22 / NCAA Facility Standards / ASHRAE 90.1-2022

Technical Requirements

  • 50 fc competitive; 75 fc broadcast; 30 fc recreational minimum
  • Uniformity ≤2:1 on competitive court surfaces
  • Vertical illuminance ≥50% of horizontal at net/basket height
  • Glare control per IES RP-6 Class III or better
  • Flicker-free for broadcast and smartphone video
  • Impact-resistant lens for ball-strike zones

Recommended Specifications

280–320W for 35–45 ft gymnasium vault ceilings160–240W for 22–30 ft fitness centers and multipurpose rooms4000–5000K CCT for athletic visual acuityContinuous rows parallel to court long axis0-10V scene dimming with preset controller for multi-use facilities

Installation Notes

  • Mount minimum 23 ft AFF (backboard clear height) with fixtures offset 4 ft inside court sidelines to prevent overhead glare
  • Orient rows parallel to court long axis — perpendicular rows create transverse glare for players moving baseline to baseline
  • Install separate dimming zones for court, bleacher seating, and auxiliary areas for independent scene control
  • Verify vertical-to-horizontal ratio at net height with LightSpec AI before finalizing layout

Regional Compliance Notes

California Title 24 mandates occupancy-based shutoff in gymnasiums unoccupied >20 minutes

ASHRAE 90.1-2022 gymnasium LPD is 1.1 W/sf — A-LHB-02 at 320W achieves 0.5–0.8 W/sf

No accessories available for this product.

Quick Summary

The A-LHB-NV/HV Series Linear High Bay offers 160W to 320W at 130 lm/W, UL and ETL certified, with 1-10V dimming, dual voltage 120-277V and 347-480V, CRI 80, and 4000K/5000K CCT options.

Frequently Asked Questions

What voltage options does the A-LHB Series support?
Normal voltage (120-277V) and high voltage (347-480V) models available for both standard commercial and industrial electrical systems.
Is the A-LHB Series dimmable?
Yes, 1-10V dimming is built in for adjustable light output based on occupancy, daylight, or task requirements.
What certifications does it have?
Dual UL and ETL certified for maximum safety compliance in warehouse, manufacturing, and distribution facilities.
What wattage options are available?
160W, 165W, 225W, and 320W to match different ceiling heights and illumination requirements.