A-HBL 2FT and 4FT LED linear high bay light set 5000K frosted lens, 4-step power adjustable industrial highbay fixtures for warehouse lighting
A-HBL2/4FT · Linear High Bay Lights

Linear High Bay Light A-HBL2/4FT

Replace Every Fluorescent High Bay Strip — Without Redesigning the Electrical La

SKU: A-HBL2125W-NV-5K-120D-WH|
In Stock
ETL Listed
5-Year Warranty
$112.00

Volume pricing available

Pro & Volume Pricing Available

Contractors, distributors, and trade partners — create a Pro account for exclusive pricing, or request a quote for multi-unit projects.

📦 Sold in cases of 4. Full cartons ship more efficiently.
In Stock — Ships within 1-2 business days from CA
Free shipping on orders over $499
Need help? (626) 364-9198 or sales@auvolar.com

Replace Every Fluorescent High Bay Strip — Without Redesigning the Electrical Layout.

2FT and 4FT linear high bays with 4-step field-adjustable wattage, 165 lm/W, 0-10V dimming, and 12V auxiliary output for sensors. The direct replacement for T5HO and T8 fluorescent high bays that uses the same mounting points and delivers 3x the light per watt.

4-Step Power Adjustment in the Field — Get the Light Level Right

2FT models adjust between 95/105/115/125W; 4FT models between 190/210/230/250W. When the lighting plan doesn't match reality — aisles are darker than expected, or zones are over-lit — adjust on-site instead of ordering different fixtures.

165 lm/W Means Massive Energy Savings Over Fluorescent

A 4-lamp T5HO fixture pulls 234W and delivers ~80 lm/W. This fixture delivers 165 lm/W — double the efficiency. That's 50%+ energy savings while potentially increasing light levels.

12V Auxiliary Output Powers Sensors Without Extra Wiring

Built-in 12V AUX output provides power for occupancy sensors, daylight sensors, and IoT devices directly from the fixture. No separate low-voltage wiring run, no additional power supply, no extra installation labor.

PIR/Motion Sensor Compatible for Zone Control

Pair with compatible motion sensors for automatic dimming in unoccupied aisles and zones. In large warehouses with intermittent traffic, sensor control can reduce lighting energy by 40–60% beyond the base LED savings.

120–277V and 277–480V Options — Both Available

Standard commercial voltage and high-voltage industrial circuits are both covered. Specify the right input voltage at order and avoid field surprises when the existing circuit doesn't match the fixture.

Efficacy

165 lm/W
Double the efficiency of T5HO fluorescent high bays

Max Output

53,000 lm
Enough light to replace multi-lamp fluorescent bays one-for-one

Aux Power

12V Built-In
Powers sensors without separate low-voltage wiring

Adjustment

4-Step Wattage
Fine-tune output on-site to match actual conditions

LightSpec AI

Free Lighting Layout
IES-based photometric simulation
165 lm/W
Efficacy
53,000 lm
Max Output
12V Built-In
Aux Power
4-Step Wattage
Adjustment

Electrical

Voltage120-277VAC
Dimming12V Aux Power 4-Step Power Adjustable Highbay Fixt

Optical

Efficacy165lm/W
Lumens5000lm
Distribution TypeNarrow
Max Lumens53000lm
CCT Options5000K

Physical

MountingPendant or chain mount

Certification

CertificationsUL
UL ListedETL listed
DLC PremiumDLC Premium

📦 Shipping & Dimensions

ModelProduct WeightPackage WeightPackage Dimensions (L×W×H)Units/Carton
125W25.2 lbs25.2 lbs26.5" × 11" × 14.7"4
250W42.2 lbs42.2 lbs48.6" × 11" × 14.7"4

Photometric Performance Data

Professional IES-standard luminous flux measurements at 25°C, 4000K Ra70. Data certified for lighting design calculations and municipal specifications.

Standards Compliance

Based on max wattage lumen output per optic. Actual compliance depends on layout design and fixture count.

🏆
FIFA A
≥ 2400 lux avg
120°
FIFA C
≥ 1000 lux avg
120°
🏈
IES RP-6 Class I
≥ 100 fc avg
120°
🎾
IES RP-6 Class III
≥ 30 fc avg
120°

Beam Pattern & CBCP

Peak Center Beam Candlepower and throw ratings by optic.

120°
120° optic
Peak CBCP13,130 cd
Beam Angle120°
Throw RatingWide Flood (<30ft)
Wide area coverage · Low-mount <30ft · Recreational

⚡ Quick Project Estimator

Select your sport and level for an instant fixture recommendation.

Recommended Optic
60°
Fixture Count
48-72
Pole Layout
4-6 poles
Target Level
500-1000 lux (FIFA C/D)
Mounting Height
50-60ft
Get Full Photometric Layout (Free) →

Custom AGi32-grade simulation with foot-candle grid, uniformity ratios, and pole spacing

Lumen Output (lm)

Tested per IESNA LM-79-19 at 25°C, EVERFINE GO-2000A goniophotometer

Optic95W105W115W125W190W210W230W250W
120° ()15,67517,32518,97520,62531,35034,65037,95041,250
Efficacy (lm/W)165165165165165165165165

Efficacy Comparison

lm/W — higher is better

Light A-HBL2/4FT (this product)
165 lm/W
Industry LED Average
130 lm/W
HPS (High-Pressure Sodium)
110 lm/W
Metal Halide
90 lm/W

* Peak efficacy measured from LM-79 test data. Competitor values are industry typical ranges.

IES File Downloads

IESNA LM-63-2002 format · Compatible with AGi32, DIALux, Relux, Visual

🔆 Run a Free Photometric Simulation

Upload your floor plan and let LightSpec AI calculate foot-candle levels, uniformity ratios, and recommended pole spacing — in under 60 seconds.

Try LightSpec AI →

💡 LED Upgrade ROI Calculator

See the financial case for switching to LED in seconds.

Annual Energy Savings
$3,784
💰
Energy Reduction
54.0%
Payback Period
4.0 yrs
10-Year Net Savings
$22,843
CO₂ Reduction
13.5 tons/yr
DLC Utility Rebate Estimate
$2,000
~$100/fixture avg
Payback timeline4.0 of 10 yrs

* Calculations based on standard operating conditions. Actual savings depend on local utility rates and rebate availability. CO₂ based on EPA eGRID national avg (0.855 lbs/kWh).

High-Efficacy Linear High Bay for Cost-Sensitive High-Ceiling Projects

The A-HBL2/4FT delivers industry-leading 165 lm/W efficacy across 95–250W with ETL certification and IP65 protection — the optimal balance of performance, efficiency, and value for warehouses, production, retail, cold storage, and recreation.

📦

VNA & Racking Aisle Warehouses

Distribution warehouses with 8–12 ft wide aisles and 25–40 ft rack heights need directional vertical illumination that reaches every pick face from floor to top shelf — a requirement where the A-HBL2/4FT's 165 lm/W efficacy delivers a decisive cost advantage. At 250W, the fixture produces 41,250 lumens while consuming just 250W — matching the output of fixtures rated 15–20% higher in wattage from competitors with lower efficacy ratings. This efficiency advantage compounds across a 200,000+ sf distribution center: 165 lm/W versus 140 lm/W saves 15–20% on fixture count, reducing both purchase cost and installation labor. IES RP-7-21 requires 30–50 fc horizontal at floor level with ≥1 fc vertical at the highest pick face and ≤3:1 uniformity — specifications the A-HBL2 linear optics achieve in aisles where round fixtures cannot. The 0-10V dimming interface supports occupancy-based aisle switching that reduces energy by 35–50% in facilities with variable utilization patterns. ETL certified for code compliance. At $0.12/kWh and 20-hour operation, the 165 lm/W efficacy delivers payback under 15 months versus HID. Plan your layout free with LightSpec AI to determine exact fixture count and spacing.

Standard: IES RP-7-21 / OSHA 29 CFR 1926.56 / ASHRAE 90.1-2022

Technical Requirements

  • 30–50 fc horizontal illuminance at floor level in active aisles
  • ≥1 fc vertical illuminance at highest pick face (IES RP-7-21)
  • Vertical uniformity ≤3:1 floor to top rack shelf
  • IP65 for dust-intensive warehouse operations
  • 0-10V dimming for per-aisle occupancy switching
  • L70 ≥100,000 hours to minimize high-ceiling re-lamp costs

Recommended Specifications

200–250W for 30–40 ft mounting heights in primary VNA aisles95–150W for 20–25 ft in standard rack and mezzanine areas5000K CCT for barcode and label scanning contrastAsymmetric aisle optics for narrow-corridor light distributionContinuous row mounting centered over aisle for uniform vertical coverage

Installation Notes

  • Center fixtures precisely over aisle — at 35 ft mounting height, 6 in. offset costs 15% vertical fc on one rack face
  • Use continuous strut channel for row alignment across aisle runs exceeding 100 ft
  • Wire to highest available voltage (277V or 480V) to reduce conductor cost on long aisle home runs
  • Set occupancy sensors to 50% standby dimming, not full off — forklift operators need minimum visibility entering aisles

Regional Compliance Notes

California Title 24-2022 mandates occupancy controls in warehouse aisles — A-HBL2 0-10V is compliant

ASHRAE 90.1-2022 warehouse LPD is 0.66 W/sf — A-HBL2 at 165 lm/W achieves 0.28–0.45 W/sf

🏭

Assembly Line & Production Facilities

Electronics assembly, food packaging, and light manufacturing lines operate at 50–100 fc with strict uniformity and color rendering requirements where lighting cost per square foot directly impacts product margin. The A-HBL2/4FT at 165 lm/W delivers more lumens per watt than any fixture in its class, meaning fewer fixtures per linear foot of production line — reducing upfront purchase, installation, and long-term maintenance costs by 15–20% compared to 140–150 lm/W alternatives. At 250W producing 41,250 lumens, a continuous row of A-HBL2 fixtures delivers 50–100 fc across 10–12 ft wide production bays with ≤1.5:1 longitudinal uniformity, eliminating the inter-fixture brightness variation where visual inspection accuracy drops. CRI >80 ensures reliable color discrimination for component identification, solder joint inspection, and finished product quality checks. The IP65 rating protects against particulates, mist, and cleaning agents without requiring additional enclosures that trap heat and reduce output. ETL certified for streamlined AHJ approvals. 0-10V dimming enables daylight harvesting in facilities with skylights or clerestories. Model your line layout free with LightSpec AI.

Standard: IES RP-7-21 / OSHA 1910.303 / NFPA 70 / IESNA DG-29

Technical Requirements

  • 50–100 fc task illuminance at work surface (36–42 in. AFF)
  • CRI ≥80 standard; ≥90 for color-critical inspection
  • Flicker <1% for machine vision and camera systems
  • Longitudinal uniformity ≤1.5:1 along production runs
  • IP65 for particulate and chemical mist environments
  • L70 100,000 hours for continuous-operation facilities

Recommended Specifications

200–250W for 25–35 ft production bay ceilings95–150W for 15–22 ft sub-assembly and packaging areas4000K general; 5000K for QC and inspection positionsEnd-to-end continuous row mounting for seamless coverage0-10V daylight harvesting with skylight integration

Installation Notes

  • Mount fixture rows directly above production line centerline for symmetric workstation illumination
  • Use strut mounting for vibration-prone environments near packaging, labeling, or material handling equipment
  • Separate lighting circuits from motor loads and VFDs to eliminate harmonic-induced flicker

Regional Compliance Notes

California Title 24 requires daylight responsive controls in manufacturing with ≥2% skylight-to-roof ratio

ASHRAE 90.1-2022 manufacturing LPD is 0.85 W/sf — A-HBL2 at 165 lm/W achieves 0.38–0.55 W/sf

🛒

Retail Warehouse & Home Improvement

Regional hardware stores, building supply centers, and wholesale club retailers need 50–75 fc in merchandise aisles with CRI ≥80 for accurate color rendering — but often on tighter budgets than national chains. The A-HBL2/4FT at 165 lm/W delivers premium lighting performance at a compelling cost-per-lumen: the highest efficacy in the linear high bay category means fewer fixtures needed to achieve target foot-candles, reducing both capital cost and installation labor by 15–25% versus 140 lm/W competitors. A 200W fixture produces 33,000 lumens — enough to light 25 linear feet of aisle to 60 fc at 25 ft mounting height. The linear form factor penetrates deep into rack canyons that round fixtures cannot effectively illuminate, making it ideal for the 15–25 ft product racking common in home improvement retail. ETL certification provides the third-party safety listing required for commercial occupancy permits. The 100,000-hour L70 life means a fixture installed today won't need replacement for 12+ years at retail operating hours. Design your store lighting free with LightSpec AI to see exact uniformity across each aisle section.

Standard: IES RP-2-22 / IES Retail Lighting Guide / ASHRAE 90.1-2022

Technical Requirements

  • 50–75 fc at shelf face height (3–10 ft AFF) in merchandise aisles
  • Vertical uniformity ≤3:1 from bottom to top shelf
  • CRI ≥80 for product color accuracy (paint, tile, flooring)
  • Flicker-free for security cameras and customer video
  • 0-10V dimming for after-hours energy savings
  • ETL listed for commercial building permit compliance

Recommended Specifications

200–250W for 25–35 ft ceiling heights in main aisle bays95–150W for 18–22 ft checkout and seasonal areas4000K CCT for warm-neutral retail environmentLinear optics aligned with merchandise aislesContinuous rows for seamless aisle illumination

Installation Notes

  • Orient fixtures parallel to aisle run — perpendicular orientation wastes 30%+ of output on rack tops
  • Reduce fixture spacing by 15% near perimeter walls where reflected light contribution drops
  • Use 277V commercial feeds for long aisle circuit runs within NEC ampacity limits

Regional Compliance Notes

California Title 24 retail LPD is 1.0 W/sf — A-HBL2 at 165 lm/W achieves 50–75 fc within 0.4–0.6 W/sf

Oregon and Washington require daylight responsive controls in retail spaces with skylight area >2%

❄️

Cold Storage & Freezer Aisles

Cold storage facilities spend $2.50–$4.00/sf/year on refrigeration energy, making every watt of heat from lighting fixtures a double cost: you pay for the electricity to create it and again for the refrigeration to remove it. The A-HBL2/4FT at 165 lm/W produces less heat per lumen than any competitor — at 250W, it generates just 60W of waste heat compared to 250W+ from the 400W HPS it replaces, reducing refrigeration load by 190W per fixture location. Across a 100,000 sf cold storage facility with 200 fixture positions, that's 38kW less refrigeration demand — saving $15,000–$25,000/year in cooling costs alone, on top of the $35,000–$50,000 in direct lighting energy savings. The IP65 fully gasketed housing withstands -40°F operation, daily humidity cycling, and chlorinated wash-down chemicals. The linear form factor delivers superior aisle coverage in the narrow pick corridors between pallet racks that define cold storage layout. ETL certification meets cold chain insurer and operator requirements. Calculate your total energy savings including refrigeration offset free with LightSpec AI.

Standard: IES RP-7-21 / NSF/ANSI 2 / USDA FSIS / ASHRAE 90.1

Technical Requirements

  • IP65 sealed against ice crystals, humidity cycling, and wash-down
  • Operating range -40°F to 131°F (-40°C to 55°C)
  • 15–25 fc floor level in freezer aisles; 30 fc at inspection zones
  • Low thermal output to minimize refrigeration offset penalty
  • Corrosion-resistant to ammonia and cleaning chemicals
  • ETL certified for cold storage insurance compliance

Recommended Specifications

200–250W for 28–40 ft freezer warehouse heights95–150W for 18–25 ft cold storage corridors5000K CCT for product date code and label inspection316 stainless steel mounting hardware exclusivelyEmergency battery backup for egress-required corridors

Installation Notes

  • Allow 30+ minutes thermal equalization before energizing after cold-environment installation
  • Use 316 stainless steel hardware only — standard galvanized corrodes within months in cold storage
  • Seal all conduit penetrations through vapor barriers with fire-rated, vapor-tight sealant to prevent ice formation at junctions

Regional Compliance Notes

California Title 24 requires ETL/UL/DLC listing for cold storage lighting receiving utility rebates

ASHRAE 90.1 cold storage LPD is 0.6 W/sf — A-HBL2 at 165 lm/W achieves 0.22–0.4 W/sf

🏋️

Fitness & Indoor Recreation Centers

Fitness clubs, YMCAs, and community recreation centers operate on tight budgets with high ceilings and diverse programming — making the A-HBL2/4FT's 165 lm/W efficacy a critical advantage. Higher efficacy means fewer fixtures to achieve 30–75 fc targets, directly reducing the capital budget for lighting in facilities where every dollar competes with equipment, flooring, and HVAC upgrades. At 250W producing 41,250 lumens in a linear pattern, continuous rows create the uniform, scallop-free illumination that group fitness classes and court sports demand — a significant visual quality improvement over point-source UFO fixtures spaced at wide intervals. IES RP-6 Class III recreational lighting requires ≤2:1 uniformity on court surfaces with careful glare control for upward-facing activities (yoga, floor exercises, stretching). The A-HBL2 directed optics achieve this without supplemental louvers that reduce output and increase cost. The 95–250W range covers everything from 18 ft fitness studio ceilings (95W) to 35 ft gymnasium peaks (250W) with a single product family for simplified specification and spare parts. 0-10V dimming enables activity-based scene presets. ETL certified. Verify your recreation facility layout free with LightSpec AI.

Standard: IES RP-6-22 / NCAA Facility Standards / ASHRAE 90.1-2022

Technical Requirements

  • 30 fc recreational; 50 fc competitive; 75 fc broadcast
  • Uniformity ≤2:1 on court and open floor areas
  • Vertical illuminance ≥50% of horizontal for ball tracking
  • Glare control per IES RP-6 Class III for upward-facing activities
  • Flicker-free for video recording and livestreaming
  • IP65 for pool-adjacent and high-humidity recreation areas

Recommended Specifications

200–250W for 28–38 ft gymnasium ceilings95–150W for 18–25 ft fitness studios and multipurpose rooms4000–5000K CCT for athletic visual performanceContinuous rows parallel to court long axis for uniform coverage0-10V scene dimming with preset controller

Installation Notes

  • Align linear rows parallel to court long axis — perpendicular rows create transverse glare for athletes
  • Mount minimum 23 ft AFF in gymnasiums with 4 ft offset inside court sidelines
  • Use vibration-dampened mounting in facilities with rooftop HVAC transmitting through bar joists
  • Program separate dimming zones for court, bleachers, and auxiliary spaces

Regional Compliance Notes

California Title 24 requires automatic shutoff in gymnasium spaces unoccupied >20 minutes

ASHRAE 90.1-2022 gymnasium LPD is 1.1 W/sf — A-HBL2 at 165 lm/W achieves 0.4–0.7 W/sf

No accessories available for this product.

Quick Summary

The A-HBL2/4FT Linear High Bay delivers 125W or 250W at 165 lm/W efficacy with up to 53,000 lumens, ETL certified, supporting 120-277V and 277-480V with 12V auxiliary power and 4-step wattage selection.

Frequently Asked Questions

What is the efficacy of the A-HBL Linear High Bay?
165 lm/W, among the highest in the linear high bay category, delivering up to 53,000 lumens for maximum energy savings.
Does it support high voltage installations?
Yes, it supports both 120-277V and 277-480V input, making it suitable for standard and high-voltage industrial electrical systems.
What is the 12V auxiliary power for?
The 12V aux output powers occupancy sensors, emergency drivers, or other accessories without additional wiring.
What wattage steps are available?
4-step wattage selection with 125W and 250W primary options, allowing field-adjustable output for different mounting heights.