Antec AN-BP LED Back Lit Panel 2x4 front view, white RAL 9003 finish, PMMA lens for high light uniformity
AN-BP-xxW-345K-xxDS · Troffers & Panels

Turnable Panel Light AN-BP-xxW-345K-xxDS

Illuminate with Precision: Turnable Panel Light AN-BP-xxW-345K-xxDS

SKU: A-BP50WS-NV-345KS-120D-WH|
In Stock
DLC Listed
ETL Listed
5-Year Warranty
$80.00

Volume pricing available

Pro & Volume Pricing Available

Contractors, distributors, and trade partners — create a Pro account for exclusive pricing, or request a quote for multi-unit projects.

📦 Sold in cases of 4. Full cartons ship more efficiently.
In Stock — Ships within 1-2 business days from CA
Free shipping on orders over $499
Need help? (626) 364-9198 or sales@auvolar.com

Illuminate with Precision: Turnable Panel Light AN-BP-xxW-345K-xxDS

Experience superior lighting with Auvolar's Turnable Panel Light, offering an impressive efficacy of 130lm/W and a versatile CCT range of 3500K/4000K/5000K. Designed for longevity, this panel light ensures a 50,000-hour lifespan, making it a reliable choice for any commercial setting.

High Efficacy

Achieve optimal brightness with an efficacy of 130lm/W, ensuring efficient energy use and superior illumination.

Versatile CCT Options

Adjust the color temperature to suit your needs with options of 3500K, 4000K, and 5000K.

Durable Design

Built to last with a 50,000-hour life design for both the driver and LED components.

Wide Voltage Compatibility

Compatible with a wide range of voltages from 100-277VAC, making it suitable for various installations.

Certified Quality

ETL and DLC listed, ensuring compliance with high safety and performance standards.

Wattage Range

20-50W
Flexible power options to meet diverse lighting needs.

Lifespan

50,000hrs
Long-lasting performance for reduced maintenance costs.

Beam Angle

120 D
Wide light distribution for even coverage.

Voltage

100-277VAC
Supports a broad range of electrical systems.

Warranty

5-Year Limited Warranty
Peace of mind with a comprehensive warranty.

LightSpec AI

Free Lighting Layout
IES-based photometric simulation
20-50W
Wattage Range
50,000hrs
Lifespan
120 D
Beam Angle
100-277VAC
Voltage
5-Year Limited Warranty
Warranty

Electrical

Dimming0-10V
Frequency50/60Hz
Voltage100-277Vac

Optical

Distribution TypeNarrow
Beam Angle120 D
CCT3500K/4000K/5000K adjustable
Efficacy130lm/W
Lumens5480lm
UGR22

Physical

IK RatingIK02
IP RatingIP20
MountingT-grid ceiling recessed

Certification

CertificationsETL,DLC Premium

Warranty

Lifespan50,000hrs life design for driver and LED
Warranty5-Year Warranty

📦 Shipping & Dimensions

ModelProduct WeightPackage WeightPackage Dimensions (L×W×H)Units/Carton
20W5 lbs5 lbs49.2" × 6.3" × 14.6"4
40W4.73 lbs4.73 lbs25.6" × 6.3" × 26.4"4
50W9.18 lbs9.18 lbs49.8" × 7.2" × 26"4

Photometric Performance Data

Professional IES-standard luminous flux measurements at 25°C, 4000K Ra70. Data certified for lighting design calculations and municipal specifications.

Standards Compliance

Based on max wattage lumen output per optic. Actual compliance depends on layout design and fixture count.

🏆
FIFA A
≥ 2400 lux avg
120°
FIFA C
≥ 1000 lux avg
120°
🏈
IES RP-6 Class I
≥ 100 fc avg
120°
🎾
IES RP-6 Class III
≥ 30 fc avg
120°

Beam Pattern & CBCP

Peak Center Beam Candlepower and throw ratings by optic.

120°
120° optic
Peak CBCP2,069 cd
Beam Angle120°
Throw RatingWide Flood (<30ft)
Wide area coverage · Low-mount <30ft · Recreational

⚡ Quick Project Estimator

Select your sport and level for an instant fixture recommendation.

Recommended Optic
60°
Fixture Count
48-72
Pole Layout
4-6 poles
Target Level
500-1000 lux (FIFA C/D)
Mounting Height
50-60ft
Get Full Photometric Layout (Free) →

Custom AGi32-grade simulation with foot-candle grid, uniformity ratios, and pole spacing

Lumen Output (lm)

Tested per IESNA LM-79-19 at 25°C, EVERFINE GO-2000A goniophotometer

Optic20W25W30W40W50W
120° ()2,6003,2503,9005,2006,500
Efficacy (lm/W)130130130130130

Efficacy Comparison

lm/W — higher is better

Light AN-BP-xxW-345K-xxDS (this product)
130 lm/W
Industry LED Average
130 lm/W
HPS (High-Pressure Sodium)
110 lm/W
Metal Halide
90 lm/W

* Peak efficacy measured from LM-79 test data. Competitor values are industry typical ranges.

IES File Downloads

IESNA LM-63-2002 format · Compatible with AGi32, DIALux, Relux, Visual

🔆 Run a Free Photometric Simulation

Upload your floor plan and let LightSpec AI calculate foot-candle levels, uniformity ratios, and recommended pole spacing — in under 60 seconds.

Try LightSpec AI →

💡 LED Upgrade ROI Calculator

See the financial case for switching to LED in seconds.

Annual Energy Savings
$3,784
💰
Energy Reduction
54.0%
Payback Period
4.0 yrs
10-Year Net Savings
$22,843
CO₂ Reduction
13.5 tons/yr
DLC Utility Rebate Estimate
$2,000
~$100/fixture avg
Payback timeline4.0 of 10 yrs

* Calculations based on standard operating conditions. Actual savings depend on local utility rates and rebate availability. CO₂ based on EPA eGRID national avg (0.855 lbs/kWh).

Backlit Panel Applications for Premium Commercial Interiors

UL-listed backlit panel with 3/4/5K CCT tuning, 0–10V dimming, and superior uniformity — designed for offices, healthcare, retail, education, and government facilities

🏢

Corporate Office & Conference Rooms

Corporate environments demand ceiling panels that deliver flawless, glare-free illumination across open offices and enclosed conference rooms — critical for productivity, video call quality, and employee wellbeing. The AN-BP backlit panel produces UGR<19 performance with superior luminance uniformity, meeting IES RP-1 recommended 40–50 fc for office tasks. UL-listed with 3/4/5K CCT tunable output and 0–10V dimming, it supports WELL Building circadian protocols and ASHRAE 90.1-2022 energy mandates simultaneously. The backlit optical design delivers higher total output and better uniformity than edge-lit panels at comparable wattage, creating a premium ceiling plane with zero visible hot spots. Offices converting from T8 fluorescent save 55–65% energy with DLC-eligible rebates of $15–30 per fixture. Use LightSpec AI free layout tool to design optimal panel density for your open office and conference configurations.

Standard: IES RP-1 / ASHRAE 90.1 / WELL Building

Technical Requirements

  • 40–50 fc at desk height per IES RP-1
  • UGR <19 for computer screen comfort per ISO 8995
  • CRI ≥80 for accurate color rendering in meetings and document review
  • 0–10V dimming (100%–10%) for AV presentation and daylight modes
  • 3/4/5K CCT selectable for building-wide consistency
  • UL listed for dry/damp locations

Recommended Specifications

4000K CCT for standard corporate office specification0–10V dimming connected to BMS for automated daylight harvestingPair with ceiling occupancy sensor for per-zone energy optimizationEmergency battery backup for conference rooms and egress corridorsOne panel per 50–64 sq ft for uniform 40–50 fc at standard ceiling heights

Installation Notes

  • Drop into standard T-bar grid — backlit panels may be slightly heavier than edge-lit; verify grid support capacity
  • Connect 0–10V dimming leads before final grid placement
  • Set CCT switch to desired Kelvin before ceiling installation — access is restricted after placement
  • For surface mount: order frame kit separately and pre-assemble before ceiling installation

Regional Compliance Notes

California Title 24 §140.6(a) requires multi-level dimming, occupancy sensors, and daylight responsive controls in offices >100 sq ft

ASHRAE 90.1-2022 §9.4.1.1(a) mandates occupancy sensors with auto-OFF in offices and conference rooms

🏥

Medical Office & Exam Rooms

Medical exam rooms need flicker-free, high-CRI panel illumination for precise skin assessment, wound care documentation, and medication verification — where lighting quality directly impacts diagnostic accuracy and patient outcomes. The AN-BP backlit panel delivers <1% flicker (IEEE 1789) at CRI ≥80, producing the 50–75 fc recommended by IES RP-29 with superior uniformity from its backlit optical architecture. The smooth, sealed diffuser permits infection-control wipe-down with hospital-grade disinfectants. 3/4/5K CCT selection allows 4000K in exam rooms for clinical clarity and 3500K in patient waiting areas for calming ambiance — settable per-room at installation. 0–10V dimming supports dual-mode operation: full exam illumination at 75 fc and reduced patient comfort at 30 fc. Plan your medical suite with LightSpec AI free tool to verify FGI-compliant illumination across all clinical spaces.

Standard: IES RP-29 / FGI Guidelines / HIPAA

Technical Requirements

  • 50–75 fc in exam rooms per IES RP-29 / FGI Guidelines
  • 30 fc in patient corridors and waiting areas
  • <1% flicker per IEEE 1789 for patient safety
  • CRI ≥80 for clinical-grade color accuracy
  • Sealed smooth diffuser for infection control wipe-down
  • 0–10V dimming for exam (75 fc) / comfort (30 fc) modes

Recommended Specifications

Maximum output for exam rooms at 50–75 fc target4000K CCT for exam rooms — optimal diagnostic visibility3500K CCT for patient corridors and waiting roomsEmergency battery backup in exam rooms and egress corridorsDual-circuit wiring for independent exam/ambient control

Installation Notes

  • Separate circuits from diagnostic imaging equipment to prevent electromagnetic interference
  • Verify flicker remains <1% at all dimming levels — test with portable flicker meter post-install
  • Offset exam room panels from direct-above-patient position to minimize facial shadows during assessment

Regional Compliance Notes

California OSHPD approval required for licensed healthcare; Title 24 §140.6 applies to medical office occupancies

ASHRAE 90.1-2022 and FGI lighting guidelines apply jointly — coordinate with healthcare lighting consultant

🛍️

Retail & Showroom Ceilings

Premium retail and showroom environments need consistent, high-CRI ceiling illumination that elevates merchandise presentation and reinforces brand quality perception. The AN-BP backlit panel delivers superior luminance uniformity compared to edge-lit alternatives — creating a continuous, bright ceiling plane with CRI ≥80 that makes product colors vibrant and accurate per IES RP-2 requirements of 50–75 fc. The backlit design eliminates the visible edge banding and center dark spots that cheapen retail aesthetics. UL-listed with 0–10V dimming, visual merchandisers can zone ceiling brightness by department: 75 fc for primary displays, 40 fc for transitional areas. DLC-eligible models qualify for $15–30 utility rebates, with 55–65% energy savings versus fluorescent delivering payback under 18 months. Design your showroom panel layout with LightSpec AI free tool for maximum visual merchandising impact.

Standard: IES RP-2 / ASHRAE 90.1 / DLC

Technical Requirements

  • 50–75 fc on merchandise areas per IES RP-2
  • CRI ≥80 for product color accuracy
  • Uniform backlit luminance — no visible edge bands or center shadows
  • UL listed / DLC eligible for utility rebate programs
  • 0–10V dimming for zone-based merchandising scenes
  • Grid or surface mount for varied retail ceiling types

Recommended Specifications

4000K CCT for neutral retail ambiance across all merchandise typesDLC-listed configuration for maximum rebate valueSupplement with accent/track lighting for featured display zonesEmergency backup fixtures along egress paths per IBCCoordinate panel dimensions with ceiling grid module for seamless aesthetic

Installation Notes

  • Align panel grid with merchandise display layout for visual coherence
  • Dim panels to 50% in fitting room areas for customer comfort
  • Document DLC listing number during installation for rebate application

Regional Compliance Notes

California Title 24 §140.6 mandates multi-level controls and daylight dimming in retail spaces >5,000 sq ft

ASHRAE 90.1-2022 Table 9.6.1 LPD varies by retail space type — verify wattage against applicable limit

📚

Educational Classrooms

Effective classroom lighting balances visual comfort for reading and screen work with energy efficiency mandates and emergency egress requirements — a combination that legacy fluorescent systems cannot achieve. The AN-BP backlit panel delivers <1% flicker with UGR<19 glare control, meeting IES RP-3 recommended 30–50 fc on student desks while supporting LEED v4.1 EQ credits through 0–10V dimmable operation. 3/4/5K CCT tunable allows districts to standardize at 4000K for optimal student alertness and reading comfort. The backlit optical design provides more uniform luminance than edge-lit panels, eliminating the perimeter bright spots and center dim zones that distract students. UL-listed with 50,000-hour rated life, districts eliminate mid-year fixture failures that disrupt instruction schedules. Model your classroom layout with LightSpec AI free tool for IES-compliant desk and whiteboard illumination.

Standard: IES RP-3 / LEED v4.1 / Title 24 / ASHRAE 90.1

Technical Requirements

  • 30–50 fc on student desks per IES RP-3
  • UGR <19 for glare-free screen and whiteboard viewing
  • <1% flicker per IEEE 1789 for student health and focus
  • 0–10V dimming: AV (15 fc) / testing (50 fc) / daylight-responsive modes
  • CRI ≥80 for instructional material color fidelity
  • 50,000-hour L70 rated life for uninterrupted academic year service

Recommended Specifications

4000K CCT for student alertness — research-supported optimal for educationDaylight sensor on window-side panel rows for automatic energy savingsVacancy sensor (manual-ON / auto-OFF) per school district policyEmergency battery backup on every third panel for 90-minute egressSurface-mount frame for classrooms without suspended grid ceilings

Installation Notes

  • Orient panel rows parallel to window walls for effective daylight-zone control
  • Pre-set CCT to 4000K before grid placement
  • Verify 0–10V dimming compatibility with classroom AV and smartboard control systems

Regional Compliance Notes

California Title 24 §140.6(a) requires multi-level dimming, daylight, and occupancy controls in all K-12 classrooms

ASHRAE 90.1-2022 §9.4.1.1(a) mandates occupancy sensors in classrooms; LEED v4.1 EQ requires per-zone lighting controllability

🏛️

Government & Municipal Buildings

Government and municipal buildings face unique procurement constraints: Buy American compliance, DLC listing for rebate maximization, ASHRAE 90.1 energy performance, and public budget accountability for every dollar spent. The AN-BP backlit panel is UL-listed and DLC-eligible, qualifying for $15–30 per panel in utility rebates that directly reduce taxpayer capital costs. At 30–50 fc per IES RP-1 with 55–65% energy savings versus fluorescent, it exceeds ASHRAE 90.1-2022 LPD targets. 3/4/5K CCT tunable output and 0–10V dimming integrate with government BMS systems for demand-response participation and peak-load reduction. The backlit architecture delivers premium visual quality appropriate for renovated civic spaces, and grid-compatible format enables phased replacement without service interruption. Run your facility energy analysis with LightSpec AI free tool to quantify savings and rebate ROI.

Standard: IES RP-1 / DLC / Buy American Act / ASHRAE 90.1

Technical Requirements

  • 30–50 fc for general office per IES RP-1
  • DLC listed for utility rebate eligibility
  • Buy American Act / TAA compliance (verify current status)
  • UL listed for dry/damp locations
  • 0–10V dimming for BMS and demand-response integration
  • ASHRAE 90.1-2022 LPD compliance for applicable space type

Recommended Specifications

4000K CCT as standard government office specificationDLC Premium for highest rebate tierVacancy sensors in private offices and conference roomsEmergency backup at corridor intersections and public egress pathsPhase deployment from highest-traffic floors for maximum visible impact and ROI

Installation Notes

  • Grid drop-in or surface-mount with frame kit — no ceiling modifications needed
  • Maintain DLC listing and Buy American documentation in procurement compliance file
  • Coordinate floor-by-floor installation with building operations for zero public service disruption

Regional Compliance Notes

California Title 24 governs all state and municipal buildings; §140.6 requires comprehensive automatic lighting controls

ASHRAE 90.1-2022 adopted in most states — confirm local amendments and addenda with municipal facilities director

No accessories available for this product.

Quick Summary

The Turnable Panel Light AN-BP-xxW-345K-xxDS by Auvolar offers 20-50W with 130lm/W efficacy, ETL certification.

Frequently Asked Questions

What is the wattage range for the Turnable Panel Light AN-BP-xxW-345K-xxDS?
The wattage range for the Turnable Panel Light AN-BP-xxW-345K-xxDS is 20-50W.
What is the efficacy of the Auvolar Turnable Panel Light?
The efficacy of the Auvolar Turnable Panel Light is 130lm/W.
What certifications does the Turnable Panel Light AN-BP-xxW-345K-xxDS have?
The Turnable Panel Light AN-BP-xxW-345K-xxDS is ETL Listed and DLC Listed.
What is the lifespan of the Turnable Panel Light AN-BP-xxW-345K-xxDS?
The lifespan of the Turnable Panel Light AN-BP-xxW-345K-xxDS is 50,000 hours.
What CCT options are available for the Turnable Panel Light AN-BP-xxW-345K-xxDS?
The CCT options available are 3500K, 4000K, and 5000K.