Troffer FIxture Light AN-TF24-NV
AN-TF24-NV · Troffers & Panels

Troffer FIxture Light AN-TF24-NV

Drop It in the Grid. Set the CCT. Walk Away for 50,000 Hours.

SKU: A-TF2440W-NV-5K-140D-WH|
In Stock
UL Listed
5-Year Warranty
From$56.00

Price varies by wattage, cct · Volume pricing available

Pro & Volume Pricing Available

Contractors, distributors, and trade partners — create a Pro account for exclusive pricing, or request a quote for multi-unit projects.

In Stock — Ships within 1-2 business days from CA
Free shipping on orders over $499
Need help? (626) 364-9198 or sales@auvolar.com

Drop It in the Grid. Set the CCT. Walk Away for 50,000 Hours.

A 2x4 LED troffer that drops directly into standard T-grid ceilings with 130 lm/W, 0-10V dimming, and 140° low-glare beam angle. The office and retail troffer retrofit that takes 10 minutes per fixture and delivers decade-long maintenance-free operation.

Drops into Standard T-Grid — No Ceiling Modification

Designed to fit standard 2x4 T-bar grid ceilings used in virtually every commercial office, retail space, and institutional building. Remove the old fluorescent troffer, lower in the LED replacement, connect — done.

130 lm/W — 60% More Efficient Than Fluorescent Troffers

Standard 2-lamp T8 fluorescent troffers deliver about 80 lm/W after ballast losses. At 130 lm/W, this LED troffer delivers significantly more light per watt, which means lower energy bills and potential fixture count reduction.

140° Low-Glare Beam Angle for All-Day Comfort

Wide beam with engineered low-glare optics reduces eye strain for office workers spending 8+ hours under the lights. Less glare means fewer complaints, better productivity, and compliance with modern lighting comfort standards.

0-10V Dimmable for BMS Integration

Connect to building management systems for scheduled dimming, daylight harvesting, and demand response. Smart buildings need dimmable fixtures — this one comes ready without additional hardware.

Efficacy

130 lm/W
60% more efficient than T8 fluorescent troffers

Beam

140°
Wide, low-glare distribution for office visual comfort

Lifespan

50,000 hrs
Maintenance-free for 10+ years at commercial operating hours

Warranty

5 Years
Full coverage — worry-free office and retail lighting

LightSpec AI

Free Lighting Layout
IES-based photometric simulation
130 lm/W
Efficacy
140°
Beam
50,000 hrs
Lifespan
5 Years
Warranty

Electrical

CRIRa80
Dimming0-10V dimming
Power Factor>0.9

Optical

Beam Angle140°
CCT5000K,3500K/4000K/5000K Adjustable
Efficacy130lm/W
Lumens5850lm

Physical

IP RatingDry/Damp location
Mounting2x4 ft recessed troffer

Certification

CertificationsUL, FCC

Warranty

Lifespan50,000 hours
Warranty5-Year Warranty

📦 Shipping & Dimensions

ModelProduct WeightPackage WeightPackage Dimensions (L×W×H)Units/Carton
50W15 lbs30 lbs50" × 6" × 26"2

Photometric Performance Data

Professional IES-standard luminous flux measurements at 25°C, 4000K Ra70. Data certified for lighting design calculations and municipal specifications.

Standards Compliance

Based on max wattage lumen output per optic. Actual compliance depends on layout design and fixture count.

🏆
FIFA A
≥ 2400 lux avg
140°
FIFA C
≥ 1000 lux avg
140°
🏈
IES RP-6 Class I
≥ 100 fc avg
140°
🎾
IES RP-6 Class III
≥ 30 fc avg
140°

Beam Pattern & CBCP

Peak Center Beam Candlepower and throw ratings by optic.

140°
140° optic
Peak CBCP1,572 cd
Beam Angle140°
Throw RatingWide Flood (<30ft)
General sports lighting application

⚡ Quick Project Estimator

Select your sport and level for an instant fixture recommendation.

Recommended Optic
60°
Fixture Count
48-72
Pole Layout
4-6 poles
Target Level
500-1000 lux (FIFA C/D)
Mounting Height
50-60ft
Get Full Photometric Layout (Free) →

Custom AGi32-grade simulation with foot-candle grid, uniformity ratios, and pole spacing

Lumen Output (lm)

Tested per IESNA LM-79-19 at 25°C, EVERFINE GO-2000A goniophotometer

Optic40W50W
140° ()5,2006,500
Efficacy (lm/W)130130

Efficacy Comparison

lm/W — higher is better

Light AN-TF24-NV (this product)
130 lm/W
Industry LED Average
130 lm/W
HPS (High-Pressure Sodium)
110 lm/W
Metal Halide
90 lm/W

* Peak efficacy measured from LM-79 test data. Competitor values are industry typical ranges.

🔆 Run a Free Photometric Simulation

Upload your floor plan and let LightSpec AI calculate foot-candle levels, uniformity ratios, and recommended pole spacing — in under 60 seconds.

Try LightSpec AI →

💡 LED Upgrade ROI Calculator

See the financial case for switching to LED in seconds.

Annual Energy Savings
$3,784
💰
Energy Reduction
54.0%
Payback Period
4.0 yrs
10-Year Net Savings
$22,843
CO₂ Reduction
13.5 tons/yr
DLC Utility Rebate Estimate
$2,000
~$100/fixture avg
Payback timeline4.0 of 10 yrs

* Calculations based on standard operating conditions. Actual savings depend on local utility rates and rebate availability. CO₂ based on EPA eGRID national avg (0.855 lbs/kWh).

2x4 Troffer Applications for Commercial Interiors

UL-listed recessed 2x4 troffer with CCT tuning, 0–10V dimming, and DLC rebate eligibility — designed for offices, healthcare, retail, education, and government facilities

🏢

Corporate Office & Conference Rooms

Corporate offices and conference rooms demand low-glare, uniform ceiling illumination that supports extended screen work and video conferencing without eye fatigue. The AN-TF24-NV 2x4 troffer delivers UGR<19 glare-free illumination at 40–50 fc per IES RP-1, with UL-listed construction and 0–10V dimming for seamless integration with building management systems. CCT tunable from 3500K–4000K allows facility managers to optimize for circadian wellness and WELL Building Standard credits. The recessed 2x4 form factor drops into standard grid ceilings with zero modifications, and the uniform edge-lit panel design eliminates the hot spots and visible LED dots that make cheap troffers unsuitable for executive spaces. Offices retrofitting from fluorescent 2x4 troffers save 50–65% on lighting energy with utility DLC rebates covering $15–30 per fixture. Use LightSpec AI free layout tool to optimize troffer spacing for your open office and conference room configurations.

Standard: IES RP-1 / ASHRAE 90.1 / WELL Building

Technical Requirements

  • 40–50 fc at desk height per IES RP-1 for office tasks
  • UGR <19 for computer screen work per ISO 8995
  • CRI ≥80 for accurate document and skin tone rendering
  • 0–10V dimming from 100% to 10% for conference AV modes
  • Standard 2x4 grid ceiling compatible (T-bar lay-in)
  • UL listed for dry/damp locations

Recommended Specifications

CCT 3500K–4000K for corporate office comfort0–10V dimming connected to BMS for daylight harvestingOne troffer per 64 sq ft for uniform 40–50 fc at 9ft ceilingPair with daylight sensor on perimeter zones for Title 24/ASHRAE complianceEmergency battery backup in conference rooms per IBC egress requirements

Installation Notes

  • Drop into 2x4 T-bar grid — no tools required for ceiling tile replacement
  • Connect 0–10V dimming leads before placing fixture in grid for access
  • Verify ceiling grid load capacity: fixture weight typically 8–12 lbs
  • Set CCT selector switch before installation — access may be limited after grid placement

Regional Compliance Notes

California Title 24 §140.6(a) requires multi-level dimming, occupancy sensors, and daylight controls in offices >100 sq ft

ASHRAE 90.1-2022 §9.4.1.1(a) mandates occupancy sensors in enclosed offices and conference rooms

🏥

Medical Office & Exam Rooms

Medical offices and exam rooms require flicker-free, high-CRI lighting for accurate patient skin assessment, wound evaluation, and medication identification — with lighting failures potentially compromising diagnostic accuracy. The AN-TF24-NV delivers <1% flicker (IEEE 1789 compliant) with CRI ≥80 at 50–75 fc per IES RP-29 healthcare recommendations. UL-listed 2x4 recessed format integrates cleanly into medical office ceiling grids, and the smooth diffuser surface allows infection-control wipe-down with standard hospital disinfectants. 0–10V dimming supports exam mode (75 fc) and patient comfort mode (30 fc) from a single fixture. The uniform panel output eliminates harsh spot-lighting that causes pupil constriction during ophthalmic assessment. Design your medical suite layout with LightSpec AI free tool to meet FGI foot-candle requirements across waiting, exam, and procedure rooms.

Standard: IES RP-29 / FGI Guidelines / HIPAA

Technical Requirements

  • 50–75 fc in exam rooms per IES RP-29 / FGI Guidelines
  • 30 fc in waiting and corridor areas per IES RP-29
  • <1% flicker per IEEE 1789 — critical for patient comfort
  • CRI ≥80 for accurate diagnostic color rendering
  • Smooth cleanable diffuser for infection control protocols
  • 0–10V dimming: exam mode (75 fc) / comfort mode (30 fc)

Recommended Specifications

Maximum wattage setting for exam rooms requiring 50–75 fc4000K CCT for diagnostic clarity in exam environments3500K CCT for waiting rooms and patient corridorsEmergency battery backup in exam rooms and egress pathsDual-circuit wiring for exam/ambient switching

Installation Notes

  • Install on clean-side circuits separate from diagnostic equipment to prevent EMI interference
  • Verify flicker performance after installation — some incompatible dimmers can introduce flicker
  • Position exam room troffers to minimize shadows on exam table — avoid placing directly above patient position

Regional Compliance Notes

California OSHPD review required for licensed healthcare facilities; Title 24 §140.6 applies to medical offices

ASHRAE 90.1-2022 and FGI jointly govern lighting in healthcare — verify integrated compliance with local AHJ

🛍️

Retail & Showroom Ceilings

Retail showrooms need uniform, high-CRI ceiling illumination that makes merchandise colors pop and creates the bright, inviting atmosphere that drives foot traffic and purchase decisions. The AN-TF24-NV troffer delivers CRI ≥80 with uniform edge-lit panel technology that eliminates visible hot spots, dark corners, and the yellowed-diffuser look of aging fluorescent troffers. At 50–75 fc per IES RP-2 retail recommendations, the 2x4 format provides seamless integration with existing grid ceilings. UL-listed with 0–10V dimming, it enables scene-setting for different retail zones — bright 75 fc for merchandise display, reduced 40 fc for fitting areas. DLC-listed models qualify for $15–30 utility rebates per fixture, and 60% energy savings versus fluorescent reduce payback to under 18 months for multi-store rollouts. Plan your showroom ceiling layout with LightSpec AI free tool to maximize visual impact across merchandising zones.

Standard: IES RP-2 / ASHRAE 90.1 / DLC

Technical Requirements

  • 50–75 fc on merchandise displays per IES RP-2
  • CRI ≥80 for accurate product color rendering
  • Uniform luminance: no visible hot spots or dark edges
  • Standard 2x4 T-bar grid compatibility
  • UL listed / DLC listed for utility rebate eligibility
  • 0–10V dimming for zone-based retail scene control

Recommended Specifications

Maximum wattage for 50–75 fc in primary merchandise zones4000K CCT for neutral retail ambiance that flatters all merchandise colorsDLC-listed configuration for utility rebate eligibilityPair with accent track lighting for featured display highlightingEmergency backup on egress path fixtures

Installation Notes

  • Install in standard 2x4 grid — coordinate with merchandising team for fixture-to-display alignment
  • Dim perimeter troffers to 60% in fitting room zones for customer comfort
  • Verify DLC listing number before submitting utility rebate application

Regional Compliance Notes

California Title 24 §140.6 requires multi-level controls and daylight dimming for retail >5,000 sq ft

ASHRAE 90.1-2022 Table 9.6.1 retail LPD allowance varies by space type — verify troffer wattage against applicable limit

📚

Educational Classrooms

Classrooms require uniform, flicker-free illumination that supports reading, writing, and digital screen work for 6–8 hours daily without causing eye strain or headaches in students and teachers. The AN-TF24-NV troffer delivers <1% flicker with UGR<19 glare control, meeting IES RP-3 recommended 30–50 fc for educational spaces. 0–10V dimming enables AV presentation mode (15 fc), testing mode (50 fc), and daylight-supplemented energy savings that earn LEED v4.1 EQ credits. UL-listed 2x4 format integrates with standard classroom ceiling grids. Districts replacing fluorescent troffers achieve 55–65% energy reduction qualifying for utility rebates of $15–30 per fixture, and the 50,000-hour rated life eliminates mid-semester lamp failures that disrupt instruction. Use LightSpec AI free classroom layout tool to verify IES uniformity across student desks and whiteboard surfaces.

Standard: IES RP-3 / LEED v4.1 / Title 24 / ASHRAE 90.1

Technical Requirements

  • 30–50 fc on student desks per IES RP-3
  • UGR <19 for glare-free screen and whiteboard viewing
  • <1% flicker per IEEE 1789 for student health and comfort
  • 0–10V dimming: AV mode (15 fc) / test mode (50 fc) / daylight supplement
  • CRI ≥80 for accurate color rendering on instructional materials
  • 50,000-hour L70 rated life to avoid mid-year replacements

Recommended Specifications

4000K CCT for optimal student alertness and reading comfortDaylight sensor on window-side rows for automatic dimmingVacancy sensor (manual-ON / auto-OFF) per school energy policyEmergency battery backup on every third troffer for 90-minute egressWire guard accessory in gymnasium and cafeteria applications

Installation Notes

  • Align rows parallel to windows for effective daylight-zone dimming control
  • Set CCT to 4000K before grid installation — optimal for educational settings
  • Test 0–10V dimming compatibility with classroom AV control systems before bulk deployment

Regional Compliance Notes

California Title 24 §140.6(a) requires multi-level dimming, daylight, and occupancy controls in K-12 classrooms

ASHRAE 90.1-2022 §9.4.1.1(a) mandates occupancy sensors in classrooms; LEED v4.1 EQ Credit requires controllable lighting per occupant zone

🏛️

Government & Municipal Buildings

Government and municipal buildings must meet federal Buy American procurement requirements, DLC listing for utility rebate eligibility, and strict energy codes — all while operating under constrained public budgets. The AN-TF24-NV troffer is UL-listed and DLC-qualified, enabling $15–30 per fixture utility rebates that significantly reduce taxpayer-funded capital costs. At 30–50 fc per IES RP-1 for general office environments, it exceeds ASHRAE 90.1-2022 LPD limits with 55–65% energy savings versus existing fluorescent systems. 0–10V dimming integrates with government building energy management systems for demand-response participation. The 2x4 grid format provides no-modification drop-in replacement during phased renovation schedules typical of public sector projects. Calculate energy savings and rebate ROI for your municipal facility with LightSpec AI free layout tool.

Standard: IES RP-1 / DLC / Buy American Act / ASHRAE 90.1

Technical Requirements

  • 30–50 fc for general office per IES RP-1
  • DLC listed for utility rebate qualification
  • Buy American Act / TAA compliant (verify current certification)
  • UL listed for dry/damp locations
  • 0–10V dimming for BMS and demand-response integration
  • ASHRAE 90.1-2022 LPD compliance at applicable space type limit

Recommended Specifications

4000K CCT for government office standardDLC Premium listing for highest rebate tier where availableVacancy sensor in private offices and conference roomsEmergency battery backup for public corridor egressPhased replacement plan: start with highest-usage floors for maximum ROI

Installation Notes

  • Drop into existing 2x4 grid — no ceiling modifications for standard government office layouts
  • Document DLC listing number and Buy American certification for procurement compliance file
  • Coordinate installation schedule with building operations to minimize public service disruption

Regional Compliance Notes

California Title 24 applies to all state/municipal buildings; §140.6 requires comprehensive lighting controls

ASHRAE 90.1-2022 is adopted by reference in most state energy codes — verify local amendments with facilities director

No accessories available for this product.

Quick Summary

The Auvolar Troffer Fixture Light AN-TF24-NV operates within a 40-50W range, offers 130 lm/W efficacy, and is UL Listed.

Frequently Asked Questions

What is the wattage range for the Auvolar Troffer Fixture Light AN-TF24-NV?
The Auvolar Troffer Fixture Light AN-TF24-NV has a wattage range of 40-50W.
What is the efficacy of the Auvolar TF24 Series Troffer?
The efficacy of the Auvolar TF24 Series Troffer is 130 lm/W.
How long is the lifespan of the Auvolar Troffer Fixture Light AN-TF24-NV?
The lifespan of the Auvolar Troffer Fixture Light AN-TF24-NV is 50,000 hours.
What are the CCT options for the Auvolar TF24 Series Troffer?
The CCT options for the Auvolar TF24 Series Troffer are 5000K and 345K.