AAB TEC A-SFPL-40W LED surface-mounted panel light front view, white finish, 2x2 size with 39mm low profile and flicker-free uniform light output
A-SFPL · Troffers & Panels

Turnable Panel Light A-SFPL

Surface Mount or T-Grid. 2x2 or 1x4. One Panel Does Both.

SKU: A-SFPL40WS-NV-345KS-110D-2*2FT-WH|
In Stock
DLC Listed
ETL Listed
5-Year Warranty
$76.00

Volume pricing available

Pro & Volume Pricing Available

Contractors, distributors, and trade partners — create a Pro account for exclusive pricing, or request a quote for multi-unit projects.

📦 Sold in cases of 4. Full cartons ship more efficiently.
In Stock — Ships within 1-2 business days from CA
Free shipping on orders over $499
Need help? (626) 364-9198 or sales@auvolar.com

Surface Mount or T-Grid. 2x2 or 1x4. One Panel Does Both.

A 39mm low-profile surface-mount panel with built-in driver that also drops into T-grid ceilings. 9-in-1 DIP switch (20/30/40W × 3500K/4000K/5000K), 133 lm/W, ETL + DLC certified. When every room has a different ceiling type, carry one fixture that handles all of them.

Surface Mount AND T-Grid Compatible — One Fixture, Two Ceiling Types

Some rooms have drop ceilings, others have drywall. This panel mounts flush on any surface at 39mm profile, or drops into standard T-grid. Carry one SKU for the entire building instead of separate surface-mount and recessed models.

2x2 and 1x4 Options — Both Ceiling Grid Standards Covered

2x2 for standard office grids, 1x4 for linear corridor grids. Same product family, same performance, same aesthetics — just different form factors for different grid configurations.

Built-In Driver = No External Driver Box

The driver is integrated into the 39mm housing — no separate driver box to mount above the ceiling, no extra connection point to fail, no fumbling with remote drivers in tight plenum spaces.

9-in-1 DIP Switch Eliminates SKU Proliferation

Three wattage steps (20/30/40W) and three CCT options (3500K/4000K/5000K) via simple DIP switch. Purchase managers order one part number. Electricians configure each fixture to match its specific room.

133 lm/W with ETL + DLC Certification

Industry-leading efficiency for the surface-mount category, with dual certification for code compliance and utility rebate eligibility. Premium performance without premium complications.

Profile

39mm
Ultra-slim surface mount — barely visible ceiling presence

Mount Options

Surface + Grid
One fixture for both ceiling types — simplifies procurement

Configurations

9-in-1
DIP switch selectable wattage and CCT

Certifications

ETL + DLC
Code-compliant and rebate-qualified

LightSpec AI

Free Lighting Layout
IES-based photometric simulation
39mm
Profile
Surface + Grid
Mount Options
9-in-1
Configurations
ETL + DLC
Certifications

Electrical

Voltage120-277Vac

Optical

Distribution TypeNarrow
Beam Angle110 D
CCT3500K/4000K/5000K changeable
CRIRa 80
Efficacy133lm/W
Lumensup to 5320lm

Physical

Mountingembedded, surface mounted, wall mounted, and suspended.

Certification

CertificationsDLC, ETL

Warranty

Lifespan50,000hours

📦 Shipping & Dimensions

ModelProduct WeightPackage WeightPackage Dimensions (L×W×H)Units/Carton
20W6.43 lbs25.7 lbs25.8" × 9.4" × 27"4
40W6.43 lbs25.7 lbs49.4" × 9.4" × 14.2"4

Photometric Performance Data

Professional IES-standard luminous flux measurements at 25°C, 4000K Ra70. Data certified for lighting design calculations and municipal specifications.

Standards Compliance

Based on max wattage lumen output per optic. Actual compliance depends on layout design and fixture count.

🏆
FIFA A
≥ 2400 lux avg
120°
FIFA C
≥ 1000 lux avg
120°
🏈
IES RP-6 Class I
≥ 100 fc avg
120°
🎾
IES RP-6 Class III
≥ 30 fc avg
120°

Beam Pattern & CBCP

Peak Center Beam Candlepower and throw ratings by optic.

120°
120° optic
Peak CBCP1,693 cd
Beam Angle120°
Throw RatingWide Flood (<30ft)
Wide area coverage · Low-mount <30ft · Recreational

⚡ Quick Project Estimator

Select your sport and level for an instant fixture recommendation.

Recommended Optic
60°
Fixture Count
48-72
Pole Layout
4-6 poles
Target Level
500-1000 lux (FIFA C/D)
Mounting Height
50-60ft
Get Full Photometric Layout (Free) →

Custom AGi32-grade simulation with foot-candle grid, uniformity ratios, and pole spacing

Lumen Output (lm)

Tested per IESNA LM-79-19 at 25°C, EVERFINE GO-2000A goniophotometer

Optic20W30W40W
120° ()2,6603,9905,320
Efficacy (lm/W)133133133

Efficacy Comparison

lm/W — higher is better

Light A-SFPL (this product)
133 lm/W
Industry LED Average
130 lm/W
HPS (High-Pressure Sodium)
110 lm/W
Metal Halide
90 lm/W

* Peak efficacy measured from LM-79 test data. Competitor values are industry typical ranges.

IES File Downloads

IESNA LM-63-2002 format · Compatible with AGi32, DIALux, Relux, Visual

🔆 Run a Free Photometric Simulation

Upload your floor plan and let LightSpec AI calculate foot-candle levels, uniformity ratios, and recommended pole spacing — in under 60 seconds.

Try LightSpec AI →

💡 LED Upgrade ROI Calculator

See the financial case for switching to LED in seconds.

Annual Energy Savings
$3,784
💰
Energy Reduction
54.0%
Payback Period
4.0 yrs
10-Year Net Savings
$22,843
CO₂ Reduction
13.5 tons/yr
DLC Utility Rebate Estimate
$2,000
~$100/fixture avg
Payback timeline4.0 of 10 yrs

* Calculations based on standard operating conditions. Actual savings depend on local utility rates and rebate availability. CO₂ based on EPA eGRID national avg (0.855 lbs/kWh).

Surface Panel Light Applications for Modern Interiors

UL-listed slim panel with CCT tuning, 0–10V dimming, and edge-lit uniformity — designed for offices, healthcare, retail, classrooms, and government facilities

🏢

Corporate Office & Conference Rooms

Modern corporate offices demand ultra-slim panel lighting that delivers uniform, glare-free illumination for all-day screen work and video conferencing. The A-SFPL surface/flush panel delivers UGR<19 performance with edge-lit LED technology, producing seamless luminance across the entire diffuser face — eliminating the visible dot pattern and hot spots of budget panels. UL-listed with CCT tunable output and 0–10V dimming, it meets IES RP-1 recommended 40–50 fc for office tasks while supporting WELL Building Standard circadian lighting credits. The slim profile mounts surface or recessed in standard grid ceilings, and uniform light output reduces eye strain during 8+ hour screen work sessions. Offices upgrading from fluorescent troffers save 50–65% on energy with DLC-eligible rebates of $15–30 per fixture accelerating ROI to under 18 months. Design your office lighting layout with LightSpec AI free tool to optimize for both IES foot-candle targets and WELL luminance requirements.

Standard: IES RP-1 / ASHRAE 90.1 / WELL Building

Technical Requirements

  • 40–50 fc at desk height per IES RP-1
  • UGR <19 for extended computer screen work per ISO 8995
  • CRI ≥80 for accurate document and video call rendering
  • 0–10V dimming from 100% to 10% for AV/presentation modes
  • UL listed for dry/damp locations
  • Surface or recessed grid mount compatibility

Recommended Specifications

CCT 3500K–4000K for corporate office comfort0–10V dimming tied to BMS for daylight harvesting on perimeter zonesPair with daylight sensor for Title 24/ASHRAE automatic dimming complianceEmergency battery backup in conference rooms per IBC egress codeOne panel per 50–64 sq ft for uniform 40–50 fc at 9ft ceiling

Installation Notes

  • For grid ceilings: drop into T-bar opening or use surface-mount frame kit
  • Connect 0–10V dimming wires before final fixture placement for access
  • Set CCT selector before mounting — switch location varies by model; check driver housing
  • Verify grid capacity for fixture weight — typical 6–10 lbs per panel

Regional Compliance Notes

California Title 24 §140.6(a) requires multi-level dimming, occupancy, and daylight controls in offices >100 sq ft

ASHRAE 90.1-2022 §9.4.1.1(a) mandates occupancy sensors in enclosed offices and conference rooms

🏥

Medical Office & Exam Rooms

Medical exam rooms require flicker-free, high-CRI panel lighting for accurate skin tone assessment, wound evaluation, and medication color verification — lighting failures in clinical settings can directly compromise patient safety. The A-SFPL delivers <1% flicker (IEEE 1789 compliant) with CRI ≥80, achieving 50–75 fc per IES RP-29 healthcare recommendations through uniform edge-lit technology. The smooth, sealed diffuser surface supports infection-control wipe-down protocols with standard clinical disinfectants including quaternary ammonium and bleach solutions. UL-listed with 0–10V dimming, it enables exam mode (75 fc) and patient comfort mode (30 fc) from a single panel. The ultra-slim profile creates a modern, clean aesthetic appropriate for patient-facing clinical environments. Plan your medical suite layout with LightSpec AI free tool to meet FGI illumination requirements across all room types.

Standard: IES RP-29 / FGI Guidelines / HIPAA

Technical Requirements

  • 50–75 fc in exam rooms per IES RP-29 / FGI Guidelines
  • 30 fc in waiting and patient corridor areas
  • <1% flicker per IEEE 1789 for patient comfort and safety
  • CRI ≥80 for diagnostic-quality color rendering
  • Smooth sealed diffuser for infection control wipe-down
  • 0–10V dimming for exam/comfort mode switching

Recommended Specifications

Maximum output setting for exam rooms at 50–75 fc4000K CCT for clinical diagnostic clarity3500K CCT for patient waiting areas and corridorsEmergency battery backup for exam rooms and egress pathsSeparate dimming zones for exam table area vs. ambient surround

Installation Notes

  • Install on clean-side circuits separate from imaging and diagnostic equipment
  • Test flicker performance with dimmer at all levels — some dimmer brands introduce flicker below 20%
  • Position panels to illuminate exam table without creating facial shadows — offset toward wall opposite entry

Regional Compliance Notes

California OSHPD review required for licensed healthcare occupancies; Title 24 §140.6 applies to medical offices

ASHRAE 90.1-2022 and FGI lighting requirements apply jointly — consult healthcare lighting specialist

🛍️

Retail & Showroom Ceilings

Retail showrooms require premium ceiling illumination that makes merchandise colors vivid and accurate while creating the bright, modern atmosphere that attracts customers and extends dwell time. The A-SFPL panel delivers CRI ≥80 with edge-lit uniformity — no visible dots, hot spots, or dark edges — creating the clean, contemporary ceiling aesthetic that defines premium retail environments. At 50–75 fc per IES RP-2, the uniform face luminance provides even ambient illumination that complements accent and track lighting. UL-listed with 0–10V dimming for zone-based scene control, it allows visual merchandisers to adjust ceiling brightness by department. DLC-eligible configurations qualify for $15–30 utility rebates, and 55–65% energy savings versus fluorescent panels deliver ROI within 18 months for multi-location retailers. Design your showroom ceiling grid with LightSpec AI free tool to maximize merchandising impact.

Standard: IES RP-2 / ASHRAE 90.1 / DLC

Technical Requirements

  • 50–75 fc on primary merchandise zones per IES RP-2
  • CRI ≥80 for accurate product color rendering
  • Uniform face luminance — no visible hot spots or edge shadows
  • UL listed / DLC eligible for utility rebate programs
  • 0–10V dimming for zone-based retail scene control
  • Surface or recessed mount for varied retail ceiling types

Recommended Specifications

4000K CCT for neutral ambiance flattering all merchandise categoriesDLC-listed option for maximum utility rebate valuePair with accent track for featured display zonesEmergency backup on egress path panels per IBCCoordinate panel size with ceiling grid module for clean aesthetic

Installation Notes

  • Align panels with merchandising grid for visual consistency between lighting and display zones
  • Dim perimeter panels to 50–60% in fitting room areas for customer comfort
  • Record DLC listing number during installation for rebate documentation

Regional Compliance Notes

California Title 24 §140.6 mandates multi-level controls and daylight dimming in retail >5,000 sq ft

ASHRAE 90.1-2022 Table 9.6.1 LPD limits vary by retail type — verify panel wattage vs. applicable limit

📚

Educational Classrooms

Classroom panel lighting must deliver flicker-free, glare-controlled illumination that supports 6–8 hours of reading, writing, and screen work without causing student fatigue or headaches. The A-SFPL panel provides <1% flicker with UGR<19 performance, meeting IES RP-3 recommended 30–50 fc for K-12 and higher education spaces. 0–10V dimming enables AV presentation mode (15 fc), standardized testing mode (50 fc), and daylight-supplemented operation that earns LEED v4.1 EQ credits. UL-listed with a slim, modern profile, it transforms dated fluorescent classrooms into contemporary learning environments. School districts replacing aging T8 troffers with A-SFPL panels save 55–65% on lighting energy, with 50,000-hour rated life eliminating disruptive mid-year fixture failures. Use LightSpec AI free classroom tool to verify desk-level uniformity and whiteboard vertical illumination.

Standard: IES RP-3 / LEED v4.1 / Title 24 / ASHRAE 90.1

Technical Requirements

  • 30–50 fc on student desks per IES RP-3
  • UGR <19 for glare-free screen and whiteboard work
  • <1% flicker per IEEE 1789 for student health
  • 0–10V dimming: AV (15 fc) / testing (50 fc) / daylight modes
  • CRI ≥80 for instructional material color accuracy
  • 50,000-hour L70 life to avoid mid-year replacements

Recommended Specifications

4000K CCT for optimal student alertness and reading comfortDaylight sensor on window rows for automatic dimmingVacancy sensor (manual-ON / auto-OFF) per school policyEmergency backup on every third panel for 90-minute egressSurface-mount frame kit for classrooms without grid ceilings

Installation Notes

  • Align panel rows parallel to windows for effective daylight-zone dimming
  • Set CCT to 4000K before installation — research supports neutral white for education
  • Test 0–10V dimming with classroom smartboard/projector controls before full deployment

Regional Compliance Notes

California Title 24 §140.6(a) requires multi-level dimming, daylight, and occupancy controls in K-12 classrooms

ASHRAE 90.1-2022 §9.4.1.1(a) mandates classroom occupancy sensors; LEED v4.1 requires controllable lighting per zone

🏛️

Government & Municipal Buildings

Government facilities must satisfy Buy American procurement requirements, DLC listing for utility rebate maximization, and stringent ASHRAE 90.1 energy limits — all under public budget scrutiny. The A-SFPL panel is UL-listed and DLC-eligible, qualifying for $15–30 utility rebates per panel that reduce taxpayer-funded capital expenditure. At 30–50 fc per IES RP-1, it delivers 55–65% energy savings versus fluorescent while exceeding ASHRAE 90.1-2022 LPD limits. 0–10V dimming integrates with government BMS platforms for demand-response participation and peak-load shedding. The slim panel format provides modern aesthetic appropriate for renovated public buildings, and drop-in grid compatibility enables phased replacement during normal business hours without service disruption. Calculate your municipal facility energy savings and rebate ROI with LightSpec AI free layout tool.

Standard: IES RP-1 / DLC / Buy American Act / ASHRAE 90.1

Technical Requirements

  • 30–50 fc for general office areas per IES RP-1
  • DLC listed for utility rebate eligibility
  • Buy American Act / TAA compliance (verify current status)
  • UL listed for dry/damp locations
  • 0–10V dimming for BMS and demand-response programs
  • ASHRAE 90.1-2022 LPD compliance for applicable space type

Recommended Specifications

4000K CCT as government office lighting standardDLC Premium listing for highest available rebate tierVacancy sensor in private offices and conference roomsEmergency backup at corridor intersections and public egress pathsPhased rollout starting with highest-occupancy floors for maximum energy ROI

Installation Notes

  • Drop into existing grid or surface mount with frame kit — no ceiling modifications required
  • Document DLC listing and Buy American certification for procurement audit file
  • Schedule installation floor-by-floor to minimize disruption to public services

Regional Compliance Notes

California Title 24 applies to all state and municipal facilities; §140.6 requires comprehensive automatic controls

ASHRAE 90.1-2022 is adopted by reference in most jurisdictions — verify local amendments with facility energy manager

No accessories available for this product.

Quick Summary

The Auvolar Turnable Panel Light A-SFPL offers 20-40W with 133lm/W efficacy and is ETL and DLC listed.

Frequently Asked Questions

What is the wattage range of the Turnable Panel Light A-SFPL?
The Turnable Panel Light A-SFPL has a wattage range of 20-40W.
What is the efficacy of the SFPL series panel light?
The efficacy of the SFPL series panel light is 133lm/W.
How long is the lifespan of the Auvolar Turnable Panel Light?
The lifespan of the Auvolar Turnable Panel Light is 50,000 hours.
What certifications does the Turnable Panel Light A-SFPL have?
The Turnable Panel Light A-SFPL is ETL Listed and DLC Listed.
What are the CCT options available for the SFPL series?
The SFPL series offers CCT options of 3500K/4000K/5000K.