4ft and 8ft UL listed LED linear strip light with field-adjustable power and CCT, damp location rated for commercial lighting
A-LSxFT · Strip Lights

Strip Light A-LSxFT

Field-Adjustable Power and CCT — Because the Lighting Plan Always Changes.

SKU: A-LSXFT45WS-NV-345KS-WH|
In Stock
UL Listed
5-Year Warranty
$60.00

Volume pricing available

Pro & Volume Pricing Available

Contractors, distributors, and trade partners — create a Pro account for exclusive pricing, or request a quote for multi-unit projects.

📦 Sold in cases of 6. Full cartons ship more efficiently.
In Stock — Ships within 1-2 business days from CA
Free shipping on orders over $499
Need help? (626) 364-9198 or sales@auvolar.com

Field-Adjustable Power and CCT — Because the Lighting Plan Always Changes.

4FT and 8FT LED strip lights with field-selectable wattage and 3CCT switching, 130 lm/W, 0-10V dimming, and sensor-ready snap-lock design. When the tenant changes their mind or the layout shifts, adjust the fixture — don't replace it.

Field-Adjustable Power — Set It to What the Space Actually Needs

Select from multiple wattage options (25/30/45W or 65/75/90W) on the fixture itself. When the lighting plan overestimated or underestimated, adjust in the field instead of returning fixtures and reordering.

3CCT Selection Matches Any Tenant Spec

Switch between 3500K, 4000K, and 5000K on the fixture. Warm for retail, neutral for offices, cool for warehouses — all from the same SKU. One part number in inventory covers every commercial application.

Snap-Lock Design for Fast Sensor and EM Installation

Integrated snap-lock luminous section lets you add emergency battery packs or sensors without removing the lens or disassembling the fixture. What used to be a 30-minute per-fixture modification takes minutes.

100,000-Hour L70 Life — Install and Forget

At 12 hours per day, that's 22+ years before the fixture drops to 70% output. For strip lights mounted across warehouse ceilings and commercial corridors, that's effectively zero re-lamping cost over the building's life.

Damp Location Rated for Commercial Applications

UL listed for damp locations — suitable for covered loading areas, mechanical rooms, and spaces where condensation occurs. No need for a separate fixture type in transitional zones.

Efficacy

130 lm/W
Maximum efficiency reduces total strip light count needed

Lifespan

100,000 hrs
L70 rated — 22+ years at 12hr/day operation

Adjustability

Wattage + CCT
Both power and color temperature adjustable on-site

Install

Snap-Lock
Rapid sensor and emergency pack integration

LightSpec AI

Free Lighting Layout
IES-based photometric simulation
130 lm/W
Efficacy
100,000 hrs
Lifespan
Wattage + CCT
Adjustability
Snap-Lock
Install

Electrical

Size4FT, 8FT
Voltage120-277V

Optical

Distribution TypeNarrow

Physical

MountingSurface mount linear strip
SensorU-Smart sensor bracket (plug and play, standalone or Bluetooth)

Certification

CertificationsUL

Warranty

LifespanL70>100,000 hours

📦 Shipping & Dimensions

ModelProduct WeightPackage WeightPackage Dimensions (L×W×H)Units/Carton
45W5.31 lbs31.9 lbs48.5" × 9.8" × 6"6
90W10.25 lbs41 lbs95.9" × 6.7" × 6.5"4

Photometric Performance Data

Professional IES-standard luminous flux measurements at 25°C, 4000K Ra70. Data certified for lighting design calculations and municipal specifications.

Standards Compliance

Based on max wattage lumen output per optic. Actual compliance depends on layout design and fixture count.

🏆
FIFA A
≥ 2400 lux avg
120°
FIFA C
≥ 1000 lux avg
120°
🏈
IES RP-6 Class I
≥ 100 fc avg
120°
🎾
IES RP-6 Class III
≥ 30 fc avg
120°

Beam Pattern & CBCP

Peak Center Beam Candlepower and throw ratings by optic.

120°
120° optic
Peak CBCP3,724 cd
Beam Angle120°
Throw RatingWide Flood (<30ft)
Wide area coverage · Low-mount <30ft · Recreational

⚡ Quick Project Estimator

Select your sport and level for an instant fixture recommendation.

Recommended Optic
60°
Fixture Count
48-72
Pole Layout
4-6 poles
Target Level
500-1000 lux (FIFA C/D)
Mounting Height
50-60ft
Get Full Photometric Layout (Free) →

Custom AGi32-grade simulation with foot-candle grid, uniformity ratios, and pole spacing

Lumen Output (lm)

Tested per IESNA LM-79-19 at 25°C, EVERFINE GO-2000A goniophotometer

Optic25W30W45W65W75W90W
120° ()3,2503,9005,8508,4509,75011,700
Efficacy (lm/W)130130130130130130

Efficacy Comparison

lm/W — higher is better

Light A-LSxFT (this product)
130 lm/W
Industry LED Average
130 lm/W
HPS (High-Pressure Sodium)
110 lm/W
Metal Halide
90 lm/W

* Peak efficacy measured from LM-79 test data. Competitor values are industry typical ranges.

IES File Downloads

IESNA LM-63-2002 format · Compatible with AGi32, DIALux, Relux, Visual

🔆 Run a Free Photometric Simulation

Upload your floor plan and let LightSpec AI calculate foot-candle levels, uniformity ratios, and recommended pole spacing — in under 60 seconds.

Try LightSpec AI →

💡 LED Upgrade ROI Calculator

See the financial case for switching to LED in seconds.

Annual Energy Savings
$3,784
💰
Energy Reduction
54.0%
Payback Period
4.0 yrs
10-Year Net Savings
$22,843
CO₂ Reduction
13.5 tons/yr
DLC Utility Rebate Estimate
$2,000
~$100/fixture avg
Payback timeline4.0 of 10 yrs

* Calculations based on standard operating conditions. Actual savings depend on local utility rates and rebate availability. CO₂ based on EPA eGRID national avg (0.855 lbs/kWh).

Strip Light Applications for Commercial & Industrial Spaces

UL-listed 25–90W CCT-tunable strip light at 120–277V — the most cost-effective LED solution for warehouses, retail backstock, corridors, mechanical rooms, and storage facilities

🏭

Warehouse Utility & Maintenance

Warehouse utility rooms, mechanical closets, and maintenance areas need reliable, cost-effective lighting that withstands dust, vibration, and infrequent access cycles. The A-LSxFT strip light delivers 25–90W CCT-tunable output at 120–277V universal voltage, producing up to 11,700 lumens for the 90W model — exceeding IES RP-7 recommended 20–30 fc for general utility areas. UL-listed construction with robust steel housing provides the durability that plastic-bodied economy fixtures lack. At $15–35 per unit, the strip light offers the lowest cost-per-lumen of any commercial LED fixture, with 60–70% energy savings versus T8 fluorescent and under 12-month payback. Use LightSpec AI free layout tool to calculate exact fixture quantity and spacing for your utility space.

Standard: IES RP-7 / OSHA 1910.303 / ASHRAE 90.1

Technical Requirements

  • 20–30 fc maintained at floor level per IES RP-7
  • UL listed for dry/damp locations
  • 120–277V universal voltage input
  • Minimum 50,000-hour L70 rated life
  • Steel housing for vibration and impact resistance
  • Surface or chain mount capability

Recommended Specifications

40W–65W for 10–14ft utility room ceilings4000K CCT for balanced visibility during maintenance tasksChain-hang mounting for adjustable height in equipment roomsPair with occupancy sensor for energy code compliance0–10V dimming for integration with BMS controls

Installation Notes

  • Surface mount with included clips or chain-hang with V-hooks — no specialized hardware required
  • Maintain 3ft clearance from high-temperature steam pipes and equipment exhaust
  • Daisy-chain wiring supported for up to 20 fixtures per 20A circuit at 277V
  • Verify branch circuit capacity before series connection

Regional Compliance Notes

California Title 24 §140.6(a) requires occupancy sensors and daylight controls in utility rooms >100 sq ft

ASHRAE 90.1-2022 §9.4.1.2 mandates auto-OFF controls in storage and utility spaces

📦

Retail Backstock & Storage

Retail backstock areas demand affordable lighting that delivers consistent 20–30 fc for safe inventory handling and barcode scanning without the cost of decorative commercial fixtures. The A-LSxFT strip light at 25–90W with CCT tuning (3500K–5000K) provides the ideal balance of performance and economy for back-of-house spaces. UL-listed at 120–277V universal input, it integrates with existing retail electrical infrastructure without transformer upgrades. At 130+ lm/W efficacy, a single 4ft 40W strip replaces two 32W T8 fluorescent tubes while cutting energy use by 60% — retail chains with 50+ locations save $30,000–80,000 annually across their backstock portfolio. Design optimal back-of-house layouts free with LightSpec AI to reduce fixture count while meeting OSHA visibility requirements.

Standard: IES RP-2 / OSHA 1926.56 / NEC 410

Technical Requirements

  • 20–30 fc at floor level for safe material handling per IES RP-2
  • UL listed for dry and damp locations
  • 120–277V universal input for standard retail power
  • CRI ≥80 for accurate label and barcode reading
  • Surface or pendant mount in 8–12ft ceiling heights
  • Minimum 0.4 uniformity ratio for aisle visibility

Recommended Specifications

25W–40W for standard 8–10ft backstock ceilings4000K CCT for neutral visibility during stocking operationsSurface mount for lowest installation costOccupancy sensor integration for after-hours energy savingsWire guard accessory for high-traffic forklift areas

Installation Notes

  • Surface mount with snap-in clips for fastest installation — under 10 minutes per fixture
  • Space fixtures at 1.0–1.2x mounting height for uniform coverage
  • Use junction box covers rated for accessible ceilings per NEC 314.29

Regional Compliance Notes

California Title 24 §140.6(a) requires occupancy sensors in retail storage rooms >100 sq ft

ASHRAE 90.1-2022 Table 9.6.1 allows 0.63 W/sq ft LPD for storage areas — verify strip light wattage meets limit

🚶

Industrial Corridors & Walkways

Industrial corridors and walkways require reliable, glare-controlled illumination for safe pedestrian and forklift traffic, with emergency egress compliance per IBC 1008. The A-LSxFT strip light at 25–90W delivers 10–20 fc corridor lighting per IES RP-7, with the wide-beam linear form factor providing excellent uniformity along narrow passages. UL-listed at 120–277V, it handles the voltage variations common in older industrial facilities. Steel housing withstands the vibration and incidental contact typical in active manufacturing environments. At $15–35 per fixture, outfitting a 500ft corridor costs 40–60% less than enclosed troffers or wraparounds while meeting identical code requirements. Validate corridor lighting uniformity with LightSpec AI free layout tool to ensure OSHA safe-walking-surface compliance.

Standard: IES RP-7 / OSHA 1910.22 / IBC 1008

Technical Requirements

  • 10–20 fc maintained at floor level per IES RP-7
  • OSHA 1910.22 safe walking surface visibility compliance
  • Emergency egress: 1 fc minimum along path per IBC 1008.3
  • UL listed for dry/damp industrial locations
  • 120–277V universal voltage for existing infrastructure
  • ≥3:1 uniformity ratio for safe corridor navigation

Recommended Specifications

25W–40W for 8–10ft corridor ceilings4000K CCT for alert industrial environment lightingContinuous row mounting for uniform linear coverageEmergency battery backup option for egress paths

Installation Notes

  • Mount in continuous rows end-to-end for seamless corridor illumination
  • Align fixture orientation parallel to walkway direction for optimal light distribution
  • Install emergency-rated fixtures at maximum 50ft intervals along egress paths per IBC

Regional Compliance Notes

California Title 24 §140.6(a) requires corridor lighting controls with auto-OFF or occupancy sensing

ASHRAE 90.1-2022 §9.4.1.1(e) mandates occupancy sensors in corridors — use ceiling-mount sensor for best coverage

Mechanical & Electrical Rooms

Mechanical and electrical rooms require UL-listed fixtures providing 30–50 fc for safe equipment identification, panel reading, and maintenance per IES RP-7, while maintaining NEC 110.26 working clearances around electrical panels. The A-LSxFT 25–90W strip light delivers high-output illumination in the slim linear profile that fits between overhead piping, ductwork, and cable trays where bulkier fixtures cannot be installed. 120–277V universal voltage eliminates transformer requirements in mixed-voltage mechanical spaces. Steel housing withstands the ambient vibration from HVAC equipment and compressors. One 65W strip light replaces two 4ft T8 fluorescent fixtures while reducing energy draw by 60% and eliminating ballast maintenance. Design your mechanical room layout with LightSpec AI to verify NEC-compliant illumination at every panel face.

Standard: IES RP-7 / NEC 110.26 / OSHA 1910.303

Technical Requirements

  • 30–50 fc at equipment panel faces per IES RP-7
  • NEC 110.26(D): illumination required for all electrical equipment rooms
  • UL listed for dry/damp locations
  • 120–277V universal voltage input
  • Minimum 36" clear working space in front of panels per NEC 110.26(A)
  • Dedicated unswitched lighting circuit per NEC 210.70(A)(3)

Recommended Specifications

65W–90W for bright, shadow-free panel illumination5000K CCT for maximum label legibility and wire color identificationSurface mount directly above equipment for targeted illuminationEmergency battery backup per NEC 700.12 for egress and critical equipment rooms

Installation Notes

  • Position fixtures to illuminate panel faces — do not mount directly above working clearance zone
  • Wire on dedicated unswitched circuit with switch at each entrance per NEC 210.70(A)(3)
  • Maintain minimum clearances from electrical panelboards per NEC 110.26
  • Use steel housing models in rooms with HVAC vibration for extended life

Regional Compliance Notes

California Title 24 §140.6(a) requires automatic controls in mechanical/electrical rooms >100 sq ft

ASHRAE 90.1-2022 §9.4.1.2 mandates auto-OFF controls — install occupancy sensor at room entrance

🔐

Self-Storage Facilities

Self-storage facilities operate 24/7 with minimal staffing, making energy-efficient, low-maintenance lighting essential for profitability. The A-LSxFT strip at 25–90W provides IES RP-7 recommended 10–20 fc in hallways and unit corridors at the lowest fixture cost in the commercial LED market. At 130+ lm/W efficacy with 120–277V universal input, a typical 200-unit facility saves $3,000–6,000 annually versus T8 fluorescent. The 50,000-hour L70 rated life means zero lamp replacements for 10+ years, eliminating the single largest maintenance expense for storage operators. Pair with ceiling-mount occupancy sensors for code-compliant vacant-area dimming that cuts operating costs another 40–60%. Use LightSpec AI free tool to plan fixture layout for your facility hallway configuration.

Standard: IES RP-7 / ASHRAE 90.1 / IBC 1008

Technical Requirements

  • 10–20 fc in hallways and common areas per IES RP-7
  • Emergency egress: 1 fc minimum along exit paths per IBC 1008.3
  • UL listed for dry/damp locations
  • 120–277V universal input for varied electrical infrastructure
  • 50,000-hour minimum L70 rated life for maintenance reduction
  • Occupancy/vacancy sensor compatibility for energy code compliance

Recommended Specifications

25W–40W for 8–10ft interior hallway ceilings4000K CCT for security camera compatibilityMotion sensor: auto-ON at 100% / dim to 20% after 15 min vacancyEmergency battery backup at corridor intersections and exitsWire guard for ground-floor units accessible to moving carts

Installation Notes

  • Mount in continuous rows centered over hallways for uniform wall-to-wall coverage
  • Install occupancy sensors at corridor intersections for maximum detection coverage
  • Group fixtures by zone (interior halls, exterior canopy, office) on separate circuits for independent control

Regional Compliance Notes

California Title 24 §140.6(a) requires occupancy sensors with auto-OFF in storage facility corridors

ASHRAE 90.1-2022 §9.4.1.1(j) mandates automatic lighting controls in self-storage — use networked occupancy system for multi-zone compliance

No accessories available for this product.

Quick Summary

The Auvolar Strip Light A-LSxFT, with a wattage range of 25-90W, is UL Listed and offers a lifespan of L70>100,000 hours.

Frequently Asked Questions

What is the wattage range for the Auvolar Strip Light A-LSxFT?
The wattage range for the Auvolar Strip Light A-LSxFT is 45-90W.
What is the lifespan of the Auvolar LSXFT series strip lights?
The lifespan of the Auvolar LSXFT series strip lights is L70>100,000 hours.
Are the Auvolar Strip Light A-LSxFT lights UL listed?
Yes, the Auvolar Strip Light A-LSxFT lights are UL Listed (#E474041).
What color temperature options are available for the Auvolar Strip Light A-LSxFT?
The Auvolar Strip Light A-LSxFT offers color temperature options of 3500K, 4000K, and 5000K.
What voltage range do the Auvolar LSXFT series strip lights support?
The Auvolar LSXFT series strip lights support a voltage range of 120-277VAC.